Specifications

Cascade Modem Manual
Copyright © 2007 Diamond Traffic Products, Inc
Page 22
S14 Wait for Dial Tone Delay: S14 determines how long
the modem will wait for dial tone when the W dial
modifier is used.
Range: 0 to 255
Units Seconds
Default 12
S24 Sleep Inactivity Timer: S24 sets the length of
inactivity before the modem enters sleep mode. Zero
disables sleep mode.
Range: 0 to 255
Units Minutes
Default 0
S30 Disconnect Inactivity Timer: S30 sets how long the
modem remains on line with no data flowing. Zero
disables the timer.
Range: 0 to 255
Units Minutes
Default 0
S38 Hang Up Delay Timer: S38 determines the
maximum delay between receipt of ATH0 command
and modem disconnect.
Range: 0 to 255
Units Seconds
Default 20
S40 Test Data Pattern: S40 sets the test pattern to be
used by the AT&T4 and AT&T5 commands.
0 = All Spaces (0)
1 = A Marks (1)
2 = Random Data
S41 V.34 Symbol Rate: S41 sets the V.34 test pattern
symbol rate to be used by the AT&T4 and AT&T5
commands.
0 = 2400 symbols/second 2400-21,600 bps
1 = 2743 symbols/second 4800-26,400 bps
2 = 2800 symbols/second 4800-26,400 bps
3 = 3000 symbols/second 4800-28,800 bps
4 = 3200 symbols/second 4800-31,200 bps
5 = 3429 symbols/second 4800-33,600 bps*
S42 Blacklisting: S42 controls the Blacklisting in the
XE5690SM. Blacklisting regulates how frequently the
modem can unsuccessfully dial a number. An
attempt to dial beyond the limit will result in a
receipt of the ‘BLACKLISTED’ result code.
S42 = 0 Disabled
S42 = 1 Enabled
S43 Dial Attempts before Blacklisting: S43 determines
how many dial attempts will be allowed before
Blacklisting blocks a call.
Range: 0 to 4
Units Number of Calls
Default 4
S44 Blacklisting Timer: S44 sets the duration of the
Blacklisting period.
Range: 0 to 255
Units Seconds
Default 180
S50 Minimum Off-Hook Duration: S50 determines the
minimum length of time the modem will remain off-
hook. An attempt to drop the line before this timer
expires will be ignored by the modem.
Range: 0 to 255
Units Seconds
Default 3