2A MOUNTING PLAN BLACKBOXX WITH CHARGING CABLE
First mount the black mounting plate with dummy on the wall. Use here for 1 of the
3 middle holes.
Attach this plate, then draw the 4 mounting holes for mounting the BlackBoxx.
These holes match to the holes in the BlackBoxx.
Remove the mounting plate and drill the 4 holes. Provide the holes with the sup plied
6mm plugs.
Mount the mountingplate again with the middle screw. Mount the BlackBoxx on the
mountingplate.
5 pcs. plugs and screws 6mm are included in the scope of supply.
3 CONNECT (GROUND) CABLES
The charger is equipped with terminals 4 mm². These terminals are coded with L1,
L2, L3, N and yellow/green as earth.
For a single-phase 230 V 3.7 kW connec-
tion only connect L1, N and earth. For 3
phase 400 V, connect 11 kW L1, L2, L3, N
and earth.
If an earthing cable is used, the following
must be observed make sure that the
bare jacket is connected with the sup-
plied shrink tubing is shielded.
Attention: The charger is phase sensitive, make sure the blue Zero wire is connec-
ted to the blue N terminal. The charger is equipped with a 6 amp control current
protection 5HS3.