3.12 Combustion air system
Note
Instructions for the combustion air system
The combustion air opening must remain free at all times.
Lay the combustion air inlet so
that exhaust gases cannot be drawn in as combustion air.
that fuel fumes that may occur cannot be drawn into the fresh
air intake of the vehicle or heater.
Do not direct the combustion air intake against the vehicle's air
stream.
The combustion air inlet must not become clogged with dirt and
snow.
Lay the combustion air system sloping slightly downwards. If
necessary, make a drain hole of approx. Ø 5 mm at the lowest
point to drain off condensation.
If necessary, use fastening clips or cable ties to fix the flexible
combustion air hose to the vehicle in suitable places.
3.12.1 Mounting the combustion air system
A combustion air intake silencer with a flexible pipe (di 20mm),
760mm long, is included in the installation kit.
Push the flexible pipe from the combustion air intake silencer onto
the combustion air connection socket of the heater and fix with a
screw clamp (tightening torque 3
+0.5
Nm), see Picture 18.
If necessary, shorten the flexible pipe from the combustion air
intake silencer according to the installation conditions. Ensure a
clean cut edge. Small cut-offs could block the combustion air fan.
Note
Note and follow the regulations and safety instructions for this
chapter
from page 9.
max. 760 mm
max. 2 m
min. 200 mm
min. 200 mm
min. 150 mm
Picture 18
1 Heater
2 Combustion air intake silencer
3 Flexible exhaust pipe
4 Exhaust silencer
5 Exhaust pipe end with end sleeve
6 Spacer ring
24 25.2933.90.0001.0A EN | 06.2018
Technical Description | Hydronic S3 Economy