User's Manual

 45
Specifications
Note: The embedded modules use a supervisory circuit with a 2.93V reset threshold. When
VCC falls to the threshold voltage, a reset pulse is issued, holding the output in active state.
When power rises above 2.93V, the reset remains for approximately 200 ms to allow the
system clock and other circuits to stabilize.
Warning: The rise time of the 3.3v power supply must be between 700 mS and 140ms and
the inrush current must be limited to less than 2 A. A rise time outside of these limits may
cause the device to malfunction and give a 3-1-3 diagnostic error.
Operating Conditions
Symbol Description Min Typ Max Unit
V
CC
Supply Voltage 3.14 3.3 3.45 V
n/a Power Supply Ripple 40 mVpp
I
CC
Supply Current 390 630 mA
I
IL
Input Current as “0”
(16.5K equivalent pull-up)
200 μA
I
IH
Input Current as “1”
(16.5K equivalent pull-up)
-10 10 μA
I
OZ
HighZ Leakage Current -10 10 μA
I
OD
Output Drive Strength 2 mA
C
IO
Pin Capacitance (V
O
=0) 4 pF
Inputs
Symbol Description Min Typ Max Unit
V
IH
Input High Voltage 2 V
CC
+0.3
V
V
IL
Input Low Voltage V
SS
-0.3 0.2*V
CC
V
Outputs
Symbol Description Min Typ Max Unit
V
OH
Output High Voltage 2.4 3.45 V
V
OL
Output Low Voltage 0 0.4 V