Reference Manual

. . . . .
www.digiembedded.com 132
The maximum component case temperature must remain below the maximum,
measured at the devices shown in the figure below.
When attaching thermocouples, please follow the guidelines listed below:
Carefully remove any labels or other foreign material from the component.
Ensure an adhesive with high thermal conductivity is used. Use as little
adhesive as possible.
Make sure the thermocouple is touching the case of the component and not
"floating" in the adhesive.
The use of precision, fine-wire K-type thermocouples is strongly
recommended.
Omega Engineering P/N 5TC-TT-K-36-72, or similar
recommendations management in applications with operating temperatures at the high end or beyond
the specified standard ambient temperature range.
Providing air movement will improve heat dissipation.
The host PCB plays a large part in dissipating the heat generated by the
module. A large copper plane located on the host ground PCB will improve the
heat dissipation capabilities of the PCB.
Measure Tcase of U22
Measure Tcase of U3