User Manual


47
Specifications
Note
The embedded modules use a supervisory circuit with a 2.93V reset threshold.
When VCC falls to the threshold voltage, a reset pulse is issued, holding the
output in active state. When power rises above 2.93V, the reset remains for
approximately 200 ms to allow the system clock and other circuits to stabilize.
Operating Conditions
Symbol Description Min Typ Max Unit
V
CC
Supply Voltage 3.14 3.3 3.45 V
I
CC
Supply Current
Digi
Connect
EM
270
mA
Digi
Connect
Wi-EM
400
I
IL
Input Current as “0”
(57K pull-up)
—— 57 µA
I
IH
Input Current as “1”
(57K pull-up)
-10 10 µA
I
OZ
HighZ Leakage Current -10 10 µA
I
OD
Output Drive Strength 2 mA
C
IO
Pin Capacitance (V
O
=0) 4 pF
Inputs
Symbol Description Min Typ Max Unit
V
IH
Input High Voltage 2 V
CC
+0.3
V
V
IL
Input Low Voltage V
SS
-0.3 0.2*V
CC
V
Outputs
Symbol Description Min Typ Max Unit
V
OH
Output High Voltage 2.4 3.45 V
V