User's Manual
Table Of Contents
- 1. XTend RF Module
- 2. RF Module Operation
- 3. RF Module Configuration
- Programming Examples
- Command Reference Table
- Command Descriptions
- %V (Board Voltage) Command
- AM (Auto-set MY) Command
- AP (API Enable) Command
- AT (Guard Time After) Command
- BD (Interface Data Rate) Command
- BR (RF Data Rate) Command
- BT (Guard Time Before) Command
- CC (Command Sequence Character) Command
- CD (GPO2 Configuration) Command
- CF (Number Base) Command
- CN (Exit AT Command Mode) Command
- CS (GPO1 Configuration) Command
- CT (Command Mode Timeout) Command
- DB (Received Signal Strength) Command
- DT (Destination Address) Command
- E0 (Echo Off) Command
- E1 (Echo On) Command
- ER (Receive Error Count) Command
- FH (Force Wake-up Initializer) Command
- FL (Software Flow Control) Command
- FS (Forced Synch Time) Command
- FT (Flow Control Threshold) Command
- GD (Receive Good Count) Command
- HP (Hopping Channel) Command
- HT (Time before Wake-up Initializer) Command
- HV (Hardware Version) Command
- ID (Modem VID) Command
- KY (AES Encryption Key) Command
- LH (Wake-up Initializer Timer) Command
- MD (RF Mode) Command
- MK (Address Mask) Command
- MT (Multi-transmit) Command
- MY (Source Address) Command
- NB (Parity) Command
- PB (Polling Begin Address) Command
- PD (Minimum Polling Delay) Command
- PE (Polling End Address) Command
- PK (Maximum RF Packet Size) Command
- PL (TX Power Level) Command
- PW (Pin Wake-up) Command
- RB (Packetization Threshold) Command
- RC (Ambient Power - Single Channel) Command
- RE (Restore Defaults) Command
- RM (Ambient Power - All Channels) Command
- RN (Delay Slots) Command
- RO (Packetization Timeout) Command
- RP (RSSI PWM Timer) Command
- RR (Retries) Command
- RT (GPI1 Configuration) Command
- SB (Stop Bits) Command
- SH (Serial Number High) Command
- SL (Serial Number Low) Command
- SM (Sleep Mode) Command
- ST (Time before Sleep) Command
- TP (Board Temperature) Command
- TR (Transmit Error Count) Command
- TT (Streaming Limit) Command
- TX (Transmit Only) Command
- VL (Firmware Version - Verbose)
- VR (Firmware Version - Short) Command
- WA (Active Warning Numbers) Command
- WN (Warning Data) Command
- WR (Write) Command
- WS (Sticky Warning Numbers) Command
- API Operation
- 4. RF Communication Modes
- Appendix A: Agency Certifications
- Appendix B: Development Guide
- Appendix C: Additional Information
XTend™RFModule‐ProductManual
©2013DigiInternatonal,Inc. 21
Command Reference Table
XTendCommands(TheRFmodulesexpectnumericalvaluesinhexadecimal.Hexadecimalvaluesare
designatedbya“0x”prefix.Decimalequivalentsaredesignatedbya“d”suffix.)
AT
Command
Binary
Command
AT Command Name Parameter Range
Command
Category
# Bytes
Returned
Factory
Default
%V 0x3B (59d) Board Voltage 0x2CCCA - 0x5BFFA [read-only] Diagnostics 4 --
AM 0x40 (64d) Auto-set MY -- Networking & Security -- --
AP v2.x20* -- API Enable 0 - 2 Serial Interfacing 1 0
AT 0x05 (5d) Guard Time After 2 - (ATST-3) [x 100 msec] Command Mode Options 2 0x0A (10d)
BD 0x15 (21d) Interface Data Rate
0 - 8 (standard rates)
0x39 - 0x1C9C38 (non-standard rates)
Serial Interfacing 4 3
BR 0x39 (57d) RF Data Rate 0 - 1 RF Interfacing 1 1
BT 0x04 (4d) Guard Time Before 0 - 0xFFFF [x 100 msec] Command Mode Options 2 0x0A (10d)
CC 0x13 (19d) Command Sequence Character 0x20 - 0x7F Command Mode Options 1 0x2B ["+"] (43d)
CD 0x28 (40d) GPO2 Configuration 0 - 4 Serial Interfacing 1 2
CF -- Number Base 0 - 2 Command Mode Options 1 1
CN 0x09 (9d) Exit Command Mode -- Command Mode Options -- --
CS 0x1F (31d) GPO1 Configuration 0 - 4 Serial Interfacing 1 0
CT 0x06 (6d) Command Mode Timeout 2 - 0xFFFF [x 100 ms] Command Mode Options 2 0xC8 (200d)
DB 0x36 (54d) Received Signal Strength 0x6E - 0x28 [read-only] Diagnostics 2 --
DT 0x00 (0d) Destination Address 0 - 0xFFFF Networking & Security 2 0
E0 0x0A (10d) Echo Off -- Command Mode Options -- --
E1 0x0B (11d) Echo On -- Command Mode Options -- --
ER 0x0F (15d) Receive Error Count 0 - 0xFFFF Diagnostics 2 0
FH 0x0D (13d) Force Wake-up Initializer -- Sleep (Low Power) -- --
FL 0x07 (7d) Software Flow Control 0 - 1 Serial Interfacing 1 0
FS 0x3E (62d) Forced Sync Time 0 - 0xFFFF [x 10 msec] RF Interfacing 2 0
FT 0x24 (36d) Flow Control Threshold 0 - (DI buffer size - 0x11) [Bytes] Serial Interfacing 2
DI buffer size
minus 0x11
GD 0x10 (16d) Receive Good Count 0 - 0xFFFF Diagnostics 2 0
HP 0x11 (17d) Hopping Channel 0 - 9 Networking & Security 1 0
HT 0x03 (3d) Time before Wake-up Initializer 0 - 0xFFFF [x 100 msec] Sleep (Low Power) 2
0xFFFF
(65535d)
HV -- Hardware Version 0 - 0xFFFF [read-only] Diagnostics 2 --
ID 0x27 (39d) Modem VID
0x11 - 0x7FFF (user-settable)
0x8000 - 0xFFFF (factory-set, read-only)
Networking & Security 2
0x3332
(13106d)
KY 0x3C (60d) AES Encryption Key 0 - (64 hex digits all set to 'F') Networking & Security 2 0 (disabled)
LH 0x0C (12d) Wake-up Initializer Timer 0 - 0xFF [x 100 msec] Sleep (Low Power) 1 1
MD v2.x20* 0x31 (49d) RF Mode 0 - 6 Networking & Security 1 0
MK 0x12 (18d) Address Mask 0 - 0xFFFF Networking & Security 2
0xFFFF
(65535d)
MT 0x3D (61d) Multi-Transmit 0 - 0xFF Networking & Security 1 0
MY 0x2A (42d) Source Address 0 - 0xFFFF Networking & Security 2
0xFFFF
(65535d)
NB 0x23 (35d) Parity 0 - 4 Serial Interfacing 1 0
PB v2.x20* 0x45 (69d) Polling Begin Address 0 - 0xFFFF Networking & Security 2 0
PD v2.x20* 0x47 (71d) Minimum Polling Delay
0 - 0xFFFF
(Base: (x 1 ms), Remote: [x 10 ms])
Networking & Security 2 0
PE v2.x20* 0x46 (70d) Polling End Address 0 - 0xFFFF Networking & Security 2 0