User's Manual
Table Of Contents
- 1. XTend RF Module
- 2. RF Module Operation
- 3. RF Module Configuration
- Programming Examples
- Command Reference Table
- Command Descriptions
- %V (Board Voltage) Command
- AM (Auto-set MY) Command
- AP (API Enable) Command
- AT (Guard Time After) Command
- BD (Interface Data Rate) Command
- BR (RF Data Rate) Command
- BT (Guard Time Before) Command
- CC (Command Sequence Character) Command
- CD (GPO2 Configuration) Command
- CF (Number Base) Command
- CN (Exit AT Command Mode) Command
- CS (GPO1 Configuration) Command
- CT (Command Mode Timeout) Command
- DB (Received Signal Strength) Command
- DT (Destination Address) Command
- E0 (Echo Off) Command
- E1 (Echo On) Command
- ER (Receive Error Count) Command
- FH (Force Wake-up Initializer) Command
- FL (Software Flow Control) Command
- FS (Forced Synch Time) Command
- FT (Flow Control Threshold) Command
- GD (Receive Good Count) Command
- HP (Hopping Channel) Command
- HT (Time before Wake-up Initializer) Command
- HV (Hardware Version) Command
- ID (Modem VID) Command
- KY (AES Encryption Key) Command
- LH (Wake-up Initializer Timer) Command
- MD (RF Mode) Command
- MK (Address Mask) Command
- MT (Multi-transmit) Command
- MY (Source Address) Command
- NB (Parity) Command
- PB (Polling Begin Address) Command
- PD (Minimum Polling Delay) Command
- PE (Polling End Address) Command
- PK (Maximum RF Packet Size) Command
- PL (TX Power Level) Command
- PW (Pin Wake-up) Command
- RB (Packetization Threshold) Command
- RC (Ambient Power - Single Channel) Command
- RE (Restore Defaults) Command
- RM (Ambient Power - All Channels) Command
- RN (Delay Slots) Command
- RO (Packetization Timeout) Command
- RP (RSSI PWM Timer) Command
- RR (Retries) Command
- RT (GPI1 Configuration) Command
- SB (Stop Bits) Command
- SH (Serial Number High) Command
- SL (Serial Number Low) Command
- SM (Sleep Mode) Command
- ST (Time before Sleep) Command
- TP (Board Temperature) Command
- TR (Transmit Error Count) Command
- TT (Streaming Limit) Command
- TX (Transmit Only) Command
- VL (Firmware Version - Verbose)
- VR (Firmware Version - Short) Command
- WA (Active Warning Numbers) Command
- WN (Warning Data) Command
- WR (Write) Command
- WS (Sticky Warning Numbers) Command
- API Operation
- 4. RF Communication Modes
- Appendix A: Agency Certifications
- Appendix B: Development Guide
- Appendix C: Additional Information
XTend™RFModule‐ProductManual
©2013DigiInternatonal,Inc. 23
Command Descriptions
Commands in this section are listed alphabetically. Command categories are designated between
the "< >" symbols that follow each command title. By default, XTend RF Modules expect numerical
values in hexadecimal since the default value of the CF (Number Base) Parameter is '1'.
Hexadecimal values are designated by the "0x" prefix and decimal values by the "d" suffix.
%V (Board Voltage) Command
<Diagnostics> %V Command is used to read the
current voltage of the module circuit board.
Sample Output:
5.02 V (when ATCF = 0)
5051F (when ATCF = 1) *
5.02 (when ATCF = 2)
* When CF = 1 (default), a hex integer is shown
that is equal to (voltage * 65536d).
AM (Auto-set MY) Command
<Networking & Security> AM Command is used
to automatically set the MY (Source Address)
parameter from the factory-set serial number of
the module. The address is formed with bits 29,
28 and 13-0 of the serial number (in that order).
The resulting value is displayed as a result of this command.
AP (API Enable) Command
<Serial Interfacing> The AP command is used to
enable the module to operate using the frame-
based API operation.
AT (Guard Time After) Command
<Command Mode Options> AT Command is used
to set/read the time-of-silence that follows the
command sequence character (CC Command) of
the AT Command Mode Sequence (BT + CC +
AT). By default, 1 second must elapse before and
after the command sequence character.
The times-of-silence surrounding the command
sequence character are used to prevent
inadvertent entrance into AT Command Mode.
Refer to the ‘AT Command Mode’ section [p18] for
more information regarding the AT Command Mode Sequence.
AT Command: AT%V
Binary Command: 0x3B (59 decimal)
Parameter Range (read-only):
0x2CCCA - 0x5BFFA
(2.80 - 5.75 decimal)
Number of bytes returned: 4
AT Command: ATAM
Binary Command: 0x40 (64 decimal)
AT Command: ATAP
Parameter Range:0 - 2
Parameter Configuration
0
API Disabled
(Transparent Operation)
1
API enabled
(w/out escaped
characters)
2
API enabled
(with escaped
characters)
Default Parameter Value:0
Number of Bytes Returned:1
Minimum Firmware Version Required: 2.x20
AT Command: ATAT
Binary Command: 0x05 (5 decimal)
Parameter Range:2 - (ATST-3), up to 0x7FFC
[x 100 milliseconds]
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
Related Commands: BT (Guard Time Before),
CC (Command Sequence Character)