User's Manual
Table Of Contents
- 1. XTend RF Module
- 2. RF Module Operation
- 3. RF Module Configuration
- Programming Examples
- Command Reference Table
- Command Descriptions
- %V (Board Voltage) Command
- AM (Auto-set MY) Command
- AP (API Enable) Command
- AT (Guard Time After) Command
- BD (Interface Data Rate) Command
- BR (RF Data Rate) Command
- BT (Guard Time Before) Command
- CC (Command Sequence Character) Command
- CD (GPO2 Configuration) Command
- CF (Number Base) Command
- CN (Exit AT Command Mode) Command
- CS (GPO1 Configuration) Command
- CT (Command Mode Timeout) Command
- DB (Received Signal Strength) Command
- DT (Destination Address) Command
- E0 (Echo Off) Command
- E1 (Echo On) Command
- ER (Receive Error Count) Command
- FH (Force Wake-up Initializer) Command
- FL (Software Flow Control) Command
- FS (Forced Synch Time) Command
- FT (Flow Control Threshold) Command
- GD (Receive Good Count) Command
- HP (Hopping Channel) Command
- HT (Time before Wake-up Initializer) Command
- HV (Hardware Version) Command
- ID (Modem VID) Command
- KY (AES Encryption Key) Command
- LH (Wake-up Initializer Timer) Command
- MD (RF Mode) Command
- MK (Address Mask) Command
- MT (Multi-transmit) Command
- MY (Source Address) Command
- NB (Parity) Command
- PB (Polling Begin Address) Command
- PD (Minimum Polling Delay) Command
- PE (Polling End Address) Command
- PK (Maximum RF Packet Size) Command
- PL (TX Power Level) Command
- PW (Pin Wake-up) Command
- RB (Packetization Threshold) Command
- RC (Ambient Power - Single Channel) Command
- RE (Restore Defaults) Command
- RM (Ambient Power - All Channels) Command
- RN (Delay Slots) Command
- RO (Packetization Timeout) Command
- RP (RSSI PWM Timer) Command
- RR (Retries) Command
- RT (GPI1 Configuration) Command
- SB (Stop Bits) Command
- SH (Serial Number High) Command
- SL (Serial Number Low) Command
- SM (Sleep Mode) Command
- ST (Time before Sleep) Command
- TP (Board Temperature) Command
- TR (Transmit Error Count) Command
- TT (Streaming Limit) Command
- TX (Transmit Only) Command
- VL (Firmware Version - Verbose)
- VR (Firmware Version - Short) Command
- WA (Active Warning Numbers) Command
- WN (Warning Data) Command
- WR (Write) Command
- WS (Sticky Warning Numbers) Command
- API Operation
- 4. RF Communication Modes
- Appendix A: Agency Certifications
- Appendix B: Development Guide
- Appendix C: Additional Information
XTend™RFModule‐ProductManual
©2013DigiInternatonal,Inc. 54
Polling Base Configuration:
Polling Remote Configuration:
Set the MD (RF Mode) parameter (MD = 3).
Set MY (Source Address) parameter (MY = 0).
Set the sequential range of Polling Addresses using the PB (Polling Begin Address) and PE
(Polling End Address) parameters.
(Optional) Enable Acknowledged Reliable Delivery (RR >= 0). Note: Basic Reliable Delivery is
also supported. Refer to the ‘Polling Mode - Basic section for more information.
(Optional) Use the PD (Minimum Polling Delay) command to configure a delay between polls to
slow down system (if needed).
(Optional) Enable API Mode to address remotes within polling range on a packet-by-packet
basis.
Set the MD (RF Mode) parameter (MD = 4).
Configure sequential source addresses for all remote modules using the MY (Source Address)
command.
Set the DT (Destination Address) parameter to point to ‘Polling Base’ (DT = 0x0000).
(Optional) Enable Acknowledged Reliable Delivery (RR >= 0). Note: Basic Reliable Delivery is
also supported. Refer to the ‘Polling Mode - Basic section for more information.