User's Manual
Table Of Contents
- 1. XTend RF Module
- 2. RF Module Operation
- 3. RF Module Configuration
- Programming Examples
- Command Reference Table
- Command Descriptions
- %V (Board Voltage) Command
- AM (Auto-set MY) Command
- AP (API Enable) Command
- AT (Guard Time After) Command
- BD (Interface Data Rate) Command
- BR (RF Data Rate) Command
- BT (Guard Time Before) Command
- CC (Command Sequence Character) Command
- CD (GPO2 Configuration) Command
- CF (Number Base) Command
- CN (Exit AT Command Mode) Command
- CS (GPO1 Configuration) Command
- CT (Command Mode Timeout) Command
- DB (Received Signal Strength) Command
- DT (Destination Address) Command
- E0 (Echo Off) Command
- E1 (Echo On) Command
- ER (Receive Error Count) Command
- FH (Force Wake-up Initializer) Command
- FL (Software Flow Control) Command
- FS (Forced Synch Time) Command
- FT (Flow Control Threshold) Command
- GD (Receive Good Count) Command
- HP (Hopping Channel) Command
- HT (Time before Wake-up Initializer) Command
- HV (Hardware Version) Command
- ID (Modem VID) Command
- KY (AES Encryption Key) Command
- LH (Wake-up Initializer Timer) Command
- MD (RF Mode) Command
- MK (Address Mask) Command
- MT (Multi-transmit) Command
- MY (Source Address) Command
- NB (Parity) Command
- PB (Polling Begin Address) Command
- PD (Minimum Polling Delay) Command
- PE (Polling End Address) Command
- PK (Maximum RF Packet Size) Command
- PL (TX Power Level) Command
- PW (Pin Wake-up) Command
- RB (Packetization Threshold) Command
- RC (Ambient Power - Single Channel) Command
- RE (Restore Defaults) Command
- RM (Ambient Power - All Channels) Command
- RN (Delay Slots) Command
- RO (Packetization Timeout) Command
- RP (RSSI PWM Timer) Command
- RR (Retries) Command
- RT (GPI1 Configuration) Command
- SB (Stop Bits) Command
- SH (Serial Number High) Command
- SL (Serial Number Low) Command
- SM (Sleep Mode) Command
- ST (Time before Sleep) Command
- TP (Board Temperature) Command
- TR (Transmit Error Count) Command
- TT (Streaming Limit) Command
- TX (Transmit Only) Command
- VL (Firmware Version - Verbose)
- VR (Firmware Version - Short) Command
- WA (Active Warning Numbers) Command
- WN (Warning Data) Command
- WR (Write) Command
- WS (Sticky Warning Numbers) Command
- API Operation
- 4. RF Communication Modes
- Appendix A: Agency Certifications
- Appendix B: Development Guide
- Appendix C: Additional Information
XTend™RFModule‐ProductManual
©2013DigiInternatonal,Inc. 59
IC (Industry Canada) Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Labeling Requirements
Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label
on the outside of the final product must display the following text:
Contains Model XT09 Radio, IC: 1846A-9XTENDB
The integrator is responsible for its product to comply with IC ICES-003 and FCC Part 15, Sub. B -
Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts
FCC test report or CISPR 22 test report for compliance with ICES-003.
Transmitters for Detachable Antennas
This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the table above with the maximum permissible gain and required antenna impedance for
each antenna type indicated. Antenna types not included in this list, having a gain greater than the
A09-QHRSM-170 1.7" Right angle RPSMA 1.9 dBi Fixed / Mobile
A09-QRSM-380 3.8" Right angle RPSMA 1.9 dBi Fixed / Mobile
A09-QAPM-520 5.2" Articulated Screw mount Permanent 1.9 dBi Fixed / Mobile
A09-QSPM-3 3" Straight screw mount Permanent 1.9 dBi Fixed / Mobile
A09-QAPM-3 3" Articulated screw mount Permanent 1.9 dBi Fixed / Mobile
A09-QAPM-3H 3" Articulated screw mount Permanent 1.9 dBi Fixed / Mobile
Yagiantennas(approvedwhenoperatingat100mWpoweroutputorlower)
Part Number Type Connector Gain Required Antenna Cable Loss Application
A09-Y6 2 Element Yagi RPN 6.1 dBi Fixed / Mobile
A09-Y7 3 Element Yagi RPN 7.1 dBi Fixed / Mobile
A09-Y8 4 Element Yagi RPN 8.1 dBi Fixed / Mobile
A09-Y9 4 Element Yagi RPN 9.1 dBi Fixed / Mobile
A09-Y10 5 Element Yagi RPN 10.1 dBi Fixed / Mobile
A09-Y11 6 Element Yagi RPN 11.1 dBi Fixed / Mobile
A09-Y12 7 Element Yagi RPN 12.1 dBi 1 dB Fixed / Mobile
A09-Y13 9 Element Yagi RPN 13.1 dBi 2 dB Fixed / Mobile
A09-Y14 10 Element Yagi RPN 14.1 dBi 3 dB Fixed / Mobile
A09-Y14 12 Element Yagi RPN 14.1 dBi 3 dB Fixed / Mobile
A09-Y15 13 Element Yagi RPN 15.1 dBi 4 dB Fixed / Mobile
A09-Y15 15 Element Yagi RPN 15.1 dBi 4 dB Fixed / Mobile
A09-Y6TM 2 Element Yagi RPTNC 6.1 dBi Fixed / Mobile
A09-Y7TM 3 Element Yagi RPTNC 7.1 dBi Fixed / Mobile
A09-Y8TM 4 Element Yagi RPTNC 8.1 dBi Fixed / Mobile
A09-Y9TM 4 Element Yagi RPTNC 9.1 dBi Fixed / Mobile
A09-Y10TM 5 Element Yagi RPTNC 10.1 dBi Fixed / Mobile
A09-Y11TM 6 Element Yagi RPTNC 11.1 dBi Fixed / Mobile
A09-Y12TM 7 Element Yagi RPTNC 12.1 dBi 1 dB Fixed / Mobile
A09-Y13TM 9 Element Yagi RPTNC 13.1 dBi 2 dB Fixed / Mobile
A09-Y14TM 10 Element Yagi RPTNC 14.1 dBi 3 dB Fixed / Mobile
A09-Y14TM 12 Element Yagi RPTNC 14.1 dBi 3 dB Fixed / Mobile
A09-Y15TM 13 Element Yagi RPTNC 15.1 dBi 4 dB Fixed / Mobile
A09-Y15TM 15 Element Yagi RPTNC 15.1 dBi 4 dB Fixed / Mobile
Half‐waveantennas(approvedwhenoperatingat100mWpoweroutputorlower)
Part Number Type Connector Gain Application