User Manual
Table Of Contents
- About the ConnectCore® 6UL
- Module specifications
- Assembly instructions
- Moisture sensitivity and shelf life
- Mounting
- Solder paste print
- Stencil
- Coplanarity
- SMT pick and place
- SMT process parameter reference - for both castellation and LGA applications
- Reflow profiles using a ten-zone oven, SAC 305 lead-free solder paste (Alpha ...
- Vapor Phase Profile Recommendation Using IBL 309 Batch Soldering Machine, SAC...
- Vapor Phase IBL 309 batch soldering machine settings
- Conformal coating
- Certifications
ConnectCore® 6UL Hardware Reference Manual 62
LGA
pad
ConnectCore
6UL pad
ConnectCore 6UL
signal name
i.MX6UL
pad name Multiplexing Power group Comments
A19
LGA_ A19
LCD_RESET
LCD_RESET
ALT0: LCDIF_RESET
ALT1: LCDIF_CS
ALT2: CA7_MX6UL_
EVENTI
ALT3: SAI3_TX_DATA
ALT4: WDOG1_
WDOG_ANY
ALT5: GPIO3_IO04
ALT6:
ALT7:
ALT8: ECSPI2_SS3
NVCC_LCD
A20
LGA_ A20
LCD_DATA4
LCD_
DATA04
ALT0: LCDIF_DATA04
ALT1: UART8_CTS_B
ALT2:
ALT3: ENET2_1588_
EVENT2_IN
ALT4: SPDIF_SR_
CLK
ALT5: GPIO3_IO09
ALT6: SRC_BT_
CFG04
ALT7:
ALT8: SAI1_TX_DATA
NVCC_LCD
A21 LGA_A21 GND
-
-
B1
LGA_ B1
VCC_LICELL
-
VCC_LICELL Coin cell supply
B2 LGA_B2 MCA_IO1
-
MCA GPIO/ADC
B3 LGA_B3 -
-
-
B4 LGA_B4 -
-
-