User's Manual
Table Of Contents
- 1. Overview
- 2. RF Module Operation
- 3. XBee ZigBee Networks
- Introduction to ZigBee
- ZigBee Stack Layers
- Networking Concepts
- ZigBee Application Layers: In Depth
- Coordinator Operation
- Router Operation
- End Device Operation
- Channel Scanning
- 4. Data Transmission, Addressing, and Routing
- 5. Security
- 6. Network Commissioning and Diagnostics
- 7. Managing End Devices
- 8. XBee Analog and Digital IO Lines
- 9. API Operation
- API Frame Specifications
- API UART Exchanges
- Supporting the API
- API Frames
- AT Command
- AT Command - Queue Parameter Value
- ZigBee Transmit Request
- Explicit Addressing ZigBee Command Frame
- Remote AT Command Request
- Create Source Route
- AT Command Response
- Modem Status
- ZigBee Transmit Status
- ZigBee Receive Packet
- ZigBee Explicit Rx Indicator
- ZigBee IO Data Sample Rx Indicator
- XBee Sensor Read Indicator
- Node Identification Indicator
- Remote Command Response
- Over-the-Air Firmware Update Status
- Route Record Indicator
- Many-to-One Route Request Indicator
- Sending ZigBee Device Objects (ZDO) Commands with the API
- Sending ZigBee Cluster Library (ZCL) Commands with the API
- Sending Public Profile Commands with the API
- 10. XBee Command Reference Tables
- 11. Module Support
- Appendix A: Definitions
- Appendix B: Agency Certifications
- United States FCC
- OEM Labeling Requirements
- FCC Notices
- FCC-Approved Antennas (2.4 GHz)
- Europe (ETSI)
- OEM Labeling Requirements
- Restrictions
- Declarations of Conformity
- Approved Antennas
- XBee RF Module
- XBee-PRO (S2) RF Module
- XBee-PRO (S2B) RF Module
- Canada (IC)
- Transmitters for Detachable Antennas
- Detachable Antenna
- Appendix C: Migrating from ZNet 2.5 to XBee ZB
- Appendix D: Additional Information
XBee®/XBee‐PRO®ZBRFModules
©2009DigiInternational,Inc. 120
NW
Network Watchdog Timeout. Set/read the network watchdog timeout value. If NW is
set > 0, the router will monitor communication from the coordinator (or data collector)
and leave the network if it cannot communicate with the coordinator for 3 NW periods.
The timer is reset each time data is received from or sent to a coordinator, or if a many-
to-one broadcast is received.
R
0 - 0x64FF
[x 1 minute]
(up to over 17 days)
0 (disabled)
JN
Join Notification. Set / read the join notification setting. If enabled, the module will
transmit a broadcast node identification packet on power up and when joining. This
action blinks the Associate LED rapidly on all devices that receive the transmission, and
sends an API frame out the UART of API devices. This feature should be disabled for
large networks to prevent excessive broadcasts.
RE 0 - 1 0
AR
Aggregate Routing Notification. Set/read time between consecutive aggregate route
broadcast messages. If used, AR should be set on only one device to enable many-to-
one routing to the device. Setting AR to 0 only sends one broadcast
CR 0 - 0xFF 0xFF
NetworkingCommands
AT
Command
Name and Description
Node
Type
1
Parameter Range Default