User's Manual
Table Of Contents
- 1. Overview
- 2. RF Module Operation
- 3. XBee ZigBee Networks
- Introduction to ZigBee
- ZigBee Stack Layers
- Networking Concepts
- ZigBee Application Layers: In Depth
- Coordinator Operation
- Router Operation
- End Device Operation
- Channel Scanning
- 4. Data Transmission, Addressing, and Routing
- 5. Security
- 6. Network Commissioning and Diagnostics
- 7. Managing End Devices
- 8. XBee Analog and Digital IO Lines
- 9. API Operation
- API Frame Specifications
- API UART Exchanges
- Supporting the API
- API Frames
- AT Command
- AT Command - Queue Parameter Value
- ZigBee Transmit Request
- Explicit Addressing ZigBee Command Frame
- Remote AT Command Request
- Create Source Route
- AT Command Response
- Modem Status
- ZigBee Transmit Status
- ZigBee Receive Packet
- ZigBee Explicit Rx Indicator
- ZigBee IO Data Sample Rx Indicator
- XBee Sensor Read Indicator
- Node Identification Indicator
- Remote Command Response
- Over-the-Air Firmware Update Status
- Route Record Indicator
- Many-to-One Route Request Indicator
- Sending ZigBee Device Objects (ZDO) Commands with the API
- Sending ZigBee Cluster Library (ZCL) Commands with the API
- Sending Public Profile Commands with the API
- 10. XBee Command Reference Tables
- 11. Module Support
- Appendix A: Definitions
- Appendix B: Agency Certifications
- United States FCC
- OEM Labeling Requirements
- FCC Notices
- FCC-Approved Antennas (2.4 GHz)
- Europe (ETSI)
- OEM Labeling Requirements
- Restrictions
- Declarations of Conformity
- Approved Antennas
- XBee RF Module
- XBee-PRO (S2) RF Module
- XBee-PRO (S2B) RF Module
- Canada (IC)
- Transmitters for Detachable Antennas
- Detachable Antenna
- Appendix C: Migrating from ZNet 2.5 to XBee ZB
- Appendix D: Additional Information
XBee®/XBee‐PRO®ZBRFModules
©2009DigiInternational,Inc. 127
Nodetypesthatsupportthecommand :C= Coordinator,R=Router,E=EndDevice
ND
Node Discover. Discovers and reports all RF modules found. The following information
is reported for each module discovered.
MY<CR>
SH<CR>
SL<CR>
NI<CR> (Variable length)
PARENT_NETWORK ADDRESS (2 Bytes)<CR>
DEVICE_TYPE<CR> (1 Byte: 0=Coord, 1=Router, 2=End Device)
STATUS<CR> (1 Byte: Reserved)
PROFILE_ID<CR> (2 Bytes)
MANUFACTURER_ID<CR> (2 Bytes)
<CR>
After (NT * 100) milliseconds, the command ends by returning a <CR>. ND also accepts
a Node Identifier (NI) as a parameter (optional). In this case, only a module that matches
the supplied identifier will respond.
If ND is sent through the API, each response is returned as a separate
AT_CMD_Response packet. The data consists of the above listed bytes without the
carriage return delimiters. The NI string will end in a "0x00" null character. The radius of
the ND command is set by the BH command.
CRE
optional 20-Byte
NI or MY value
--
DN
Destination Node. Resolves an NI (Node Identifier) string to a physical address (case-
sensitive). The following events occur after the destination node is discovered:
<AT Firmware>
1. DL & DH are set to the extended (64-bit) address of the module with the matching
NI (Node Identifier) string.
2. OK (or ERROR)\r is returned.
3. Command Mode is exited to allow immediate communication
<API Firmware>
1. The 16-bit network and 64-bit extended addresses are returned in an API
Command Response frame.
If there is no response from a module within (NT * 100) milliseconds or a parameter is
not specified (left blank), the command is terminated and an “ERROR” message is
returned. In the case of an ERROR, Command Mode is not exited. The radius of the DN
command is set by the BH command.
CRE
up to 20-Byte printable
ASCII string
--
IS
Force Sample Forces a read of all enabled digital and analog input lines. CRE -- --
1S
XBee Sensor Sample. Forces a sample to be taken on an XBee Sensor device. This
command can only be issued to an XBee sensor device using an API remote command.
RE - -
ExecutionCommands
AT
Command
Name and Description
Node Type
1
Parameter Range Default