Specifications
38 DC-782 Operation Manual
8.2 DC-782 Error Message List
The DC-782ās alphanumeric display allows for detailed error messages. Use Table 8-1 below to find the error
message, possible causes for the error and ways to correct the
problem. If these suggestions fail to correct the
situation, please contact your DIGI dealer for assistance..
Error Message Possible Causes Corrective Action
O F When the displayed weight exceeded
capacity
+9d, or something is on the platter
when the power is on.
Remove the item on the platter.
U F When the displayed minus weight > = 9d. Rezero the scale or power the on/off button again.
ERR 01 When the communication between the main
board and the A/D board is not complete.
Contact your RLWS Distributor
ERR 02 When thereās a data flash erase error Contact your RLWS Distributor
ERR 03 When thereās a data flash program error Contact your RLWS Distributor
8 8 8 8 8 8 Happens when the scale is not stable when
th
e power is on.
Place the scale on a firm, flat surface.
tOtAl FULL When the current total overflows the register Clear the current total.
Table 8-1. DC-782 Error Message List