DS-470 Check Weighing Scale Operation Manual 73364
DS-470 SERIES OPERATING MANUAL SECTION INDEX PAGE NUMBER 1.0. GENERAL 1.1. Description 1 1 2.0. SPECIFICATIONS 2.1. Technical Specifications 2.2. Physical Dimensions 2 2 3 3.0. INSTALLATION 3.1. Unpacking 3.2. Inspection 3.3. Repackaging 3.4. DI-470 RS-232 Cable Installation 3.5. Platform Unlocking Procedure 4 4 4 4 5 6 4.0. ELECTRICAL TEST 4.1. Set-Up Procedure 4.2. Keyboard & Display Test 7 7 7 5.0. OPERATION 5.1. Keysheet and Display Layout 5.2. DS-470 Key Function Summary "See below 5.3.
DS-470 OPERATING MANUAL 1.0. GENERAL 1.1. Features The DS-470SS Check Weighing Scale offers a practical solution to a wide range of weighing applications. There are a variety of weight capacities and increments available. The display resolution is selectable from 1/3,000 to 1/15,000. It features keyboard calibration with auto-span and ON/OFF, REZERO, TARE, for one touch tare and a numeric keyboard for digital tare and set point entry. For a list of platform sizes and available capacities see page 2.
2.0. SPECIFICATIONS This section includes a detailed listing of all pertinent specifications and parameters for each of the DS-470 weighing scales. The system weighing accuracy is 0.02 % for all models and they meet or exceed the requirements of OIML, Class III, and NIST Handbook, Number 44. Â 2.
2.2. Physical Dimensions 2.3. Color LED Bar Graph LEDs provide clear indication of weight condition between minimum and maximum besides the digital weight display. Target range is determined by entering 2 set points (min and max range.) The value can be entered by any method described in section (5.6.) on pages 13 - 15. Set points alert the operator with both auditory and visual signals if weight is within the target range.
3.0. INSTALLATION This section provides the information required for installation of the DS-470 weight indicator. The following steps accomplish installation. 1. Unpacking 2. Set-up Procedure 3.1. Unpacking Each component of the DS-470 is packed in a specially designed carton. Remove each component from its carton, separate the component from its polystyrene shell assembly and set aside. Inspect the carton interior to be sure that all accessories have been removed from the carton.
3.4.
3.5.1.
4.0. ELECTRICAL TEST 4.1. Set-Up Procedure This part of the procedure is used to verify proper operation of the weighing scale. Place the scale on a reasonably level surface. Level the scale using the adjustable legs and the level bubble guide. Connect the AC power source, and press the "ON/OFF " key, the display will momentarily show all digits from 0 to 9 in a "count-up" mode. Then the display will blank, show all "8's", and enter the regular operating display.
OPERATION 5.1. Keysheet and Display Layout 5.2. DS-470 Key Function Summary "Note: For Ver 1.
5.4. Operation Procedure Overview Step 1. ----- Press ON/OFF key to turn on the power. The numerical display windows will begin with all 0’s and scroll through to all 8’s. The DS-470 is ready to weigh as shown below. 0 0 0.0000 Note: Please set scale on a firm surface and turn adjusting legs until bubble comes to the center of the level indicator. Step 2. ----- 5.5. Tare Subtraction. Step 3. ----- 5.6. Set The Min And Max Values. Step 4. ----- 5.7. Check Weighing Operation. Step 5. ----- 5.8.
SCALE OPERATION 5.5. Tare Reduction 5.5.1. Preset Tare Operation indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode 1. Enter tare weight with numeric keys. (Ex. Tare 0.900 lb.) 2. Subtract tare weight. [9] [0] [0] 2 • • [T] 2 : NET 3 • • 3 : Îgh DISPLAY WEIGHT MIN MAX 0.000 0.900 0 0 0 0 −0.900 0 0 5.5.2. One Touch Tare Operation indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode 1. Place tare weight on platter. (Ex. Tare 0.500 lb.) 2. Press the tare key. 3.
5.6.2. Programming Of Minimum And Maximum Range By Weighing indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode 1. Place weight equal to minimum value desired on platter. (Ex.0.209 lb.) 2. Press MIN key to set the minimum value. 3. Place weight equal to maximum value desired on platter. (Ex.0.309 lb.) 4. Press MAX key to set the maximum value. 2 : NET 2 3 3 : Îgh DISPLAY WEIGHT MIN 0.000 0.209 • [MIN] MAX 0 0 0 0 0.209 0.209 0 0.309 0.209 0 0.309 0.209 0.309 [MAX] 5.6.3.
5.6.4. Programming Of Minimum And Maximum Range By Weighing Target Weight Indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode 1. Place target weight on the platter. (Ex. The target weight is 0.620 lb.) 2. Press % key. 3. Press minimum weight percent by using numeric keys. ( Ex. 10%) 4. Press MIN key to set the minimum value. (Ex. 0.620 x (100% - 10%) = 0.558) 5. Press maximum weight percent by using the numeric keys. (Ex. 15%) 6. Press MAX key to the maximum value. (Ex. 0.
5.7. Check Weighing Operation (continued) 5.7.2. When filling a container Indicators TASK 1 : OPERATION 2 : NET INDICATORS 1 Weighing mode. (from 5.4.4. min • & max programming) 1. Place empty container on scale 2. Press tare key. as shown in • 5.3.2. 3. Place parts in container, when weight is within the target range the set points will operate as shown below. 4. Once weight has been • checked remove container of parts. 2 3 3 : Îgh DISPLAY WEIGHT MIN MAX 0.000 0.558 0.713 0.500 0.
6.0. RS-232 6.0.1. Communication Specs BAUD RATE START BIT STOP BIT DATA BIT PARITY BIT 1200 / 2400 / 4800 / 9600 1 BIT 1 / 2 BIT 7 / 8 BIT EVEN / ODD / NONE 6.0.2. Text Command Termination code Data Header code Weight stable CR LF 0-9 Period Comma : 0 4 B SOH NUL The end of data The end of text Numeric data Period Comma Gross weight Net weight Tare weight Set –point status Weight stable Weight unstable 6.1.3. PIN ASSIGNMENT PIN NO.
6.1.4. COMMUNICATION METHOD By specification setting (Spec 59 bit 2 & 3), the communication method may be selected from Stream (continuous output), Manual (output by pressing [½ ½] key, and Command (output by command from external device). 6.1.4.1. STREAM Data is transmitted to external device continuously. DATA STREAM: The SPEC to select whether weight stable status or not by specification setting (Spec 53 bit 3).
6.1.4.2. MANUAL Data is output by pressing [½ ½] key. User may select to transmit the data right away or to hold the command until weight becomes stable (from Spec 59 bit 1). If weight is not back to stable within a certain interval (from Spec 59 bit 0), TIME OUT ERROR will appear on the display. The two communication methods may be selected in this mode. 6.1.4.2.1. MANUAL (METHOD 1) DATA FORMAT: Example: By pressing [½ ½] key.
6.1.4.2.2.
6.1.4.3. COMMAND Data is transmitted by receiving ENQ from external device. By specification setting (Spec 59, Bit 1), it is to select to transmit the data right away or to hold the command until weight becomes stable. If weight is not back to stable within a certain interval (by specification setting Spec 59 bit 0), TIME OUT ERROR will appear on the display.
6.2. Transmit Set-Point Data 6.0.1. Transmit Set-Point Data From External Device If Set-point data from an external device spec(spec 53 bit 2) is enabled and when MAX key is pressed without entering numeric data I Operation mode, the scale would send ENQ data and the external device would send the set-point data back.
6.0.2. Transmit Set-Point Data To External Device If Set-point data to an external device spec (spec 53 bit 2 ) is enabled and when MAX key or MIN key is pressed in the in Operation mode, the scale would send DC2 or DC4 and the external device would receive the set-point data.
7.0. MAINTENANCE, CALIBRATION, TEST PROCEDURE & SERVICE This section contains information and instructions concerning maintenance of the DS-470 check weighing scale. Preventive maintenance consists of periodically cleaning the external surfaces of the instrument and should be performed as often as operating conditions warrant. The calibration procedure is designed to be an aid in maintaining the scale accuracy within specifications. The calibration procedure may also serve as a performance test procedure.
7.1.3 Continued b. Accuracy Weighing: The scale weighing accuracy can be determined by applying various known weights to the platform. Because of the scale's very high accuracy, only weights that are certifiably more accurate than the scale's specifications should be used in testing for accuracy. (NBS class "F" or higher) Since the scale owner does not normally have such certifiable weights available to him, it is suggested that the customer call their authorized DIGI dealer. 7.2.
7.3. DS-470 Specification List 7.3.1. Customer Spec Setting To change the CUSTOMER SPEC setting Indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode Enter customer spec mode [Re-zero] [1] [4] [1] Enter new spec data. Old data [0] [0] [1] [0] will be displayed in MAX window, new data will be displayed in MIN window. Advance to the next spec [MAX] number, will not save new data. Returns to previous spec, this will [MIN] not save new data entered.
Customer Specification: To enter this mode, press and hold the re-zero key, while holding the re-zero press 1 , 4 , 1. Sequence: [Re-zero] [1] [4] [1]. Spec no.
7.3.2. Weights & Measures Spec Setting To change the WEIGHTS & MEASURES SPEC setting Indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode Enter weights & measures spec mode [Re-zero] [1] [4] [2] Enter new spec data. Old data will be [0] [0] [1] [0] displayed in MAX window, new data will be displayed in MIN window. Advance to the next spec number, will not save new data. Returns to previous spec, this will not save new data entered. Clears the data to all 0’s in the MIN window.
Weight and Measures Specification : The Span Switch must be on to enter this mode. To enter this mode, press and hold the Re-zero Key, while holding the Re-zero press 1, 4, 2, then release the Re-zero key. Sequence: [Re-zero] [1] [4] [2]. Spec No. 0 1 2 3 Bit 3 Bit 2 Bit 1 Bit 0 Display Resolution Not used 0 = single range 1 = multi range 00 = 1/3000 10 = 1/12000 01 = 1/6000 11 = 1/15000 Display Weight Decimal Point Position 0 = decimal pt 000 = 00000 011 = 00.000 1 = comma 001 = 0000.0 100 = 0.
Weight and Measures Specification (continued): Spec No.
7.4. Span Switch Status To check position of SPAN SWITCH Indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode 1. Press & hold Re-zero while pressing 2, 8, 4 [Re-zero] [2] [8] [4] Scale returns to weighing mode after 3 seconds. 2 : NET 2 3 3 : Îgh DISPLAY WEIGHT MIN MAX 0.000 0 0 S-ON or S-OFF S-ON = Span switch enabled S-OFF = Span switch disabled 0.000 0 0 • • 7.5.
7.6. Calibration Mode To CALIBRATE the scale, the span switch must be enabled. Indicators TASK 1 : OPERATION INDICATORS 1 Weighing mode. 1. Press Span Switch 2. To enter calibration mode, press & hold Re-zero while pressing 8, 7, 1, 5. 3. Press Re-zero key. 4. With no weight on the platter, press [½ ½]key in order to calibrate the zero point. Span Calibration 5. Place capacity test weight on platter 6. Press [½ ½]key in order to calibrate the span. 7.
7.8.
DS-470 Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials and workmanship for one year. RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized by RLWS.