Edgeport ® USB EXPANSION MODULES Installation Guide Models: Edgeport/1 Edgeport/2 Edgeport/4 Edgeport/4r Edgeport/8 Edgeport/8r Edgeport/421 Edgeport/21 Edgeport/42 Edgeport/416 Edgeport/2c Edgeport/21c Edgeport/22c www.digi.
Table of Contents Table of Contents .................................................................................................................2 Edgeport Products ................................................................................................................1 Edgeport /1, Edgeport/2, Edgeport/4, Edgeport/4r, Edgeport/8, Edgeport/8r .....................2 Edgeport/21, Edgeport/42, Edgeport/421 ............................................................................3 Edgeport/416 ..
Edgeport Products Edgeport USB-to-Serial Converters offer an out-of-the-box alternative to serial cards for easy plug-and-play COM port expansion. Multiple serial, parallel and USB ports can be added to a PC, thin client or server in minutes — without opening the chassis or reconfiguring and rebooting the system. Its feature-rich design, reliable performance and unmatched operating system support (Windows NT 4.
Edgeport/1, Edgeport/2, Edgeport/4, Edgeport/4r, Edgeport/8, Edgeport/8r The Edgeport/2, Edgeport/4, Edgeport/4r, Edgeport/8, and Edgeport/8r from Digi International are intelligent, stackable expansion modules that connect to a PC or server running Windows 98, SE, CE, Me, NT 4.0, 2000, or Windows XP via the Universal Serial Bus (USB), providing high-speed serial connectivity. For more detailed information as well as the latest manual and technical updates, visit www.digi.com/support.
Edgeport/21, Edgeport/42, Edgeport/421 These Edgeports are multi-connector converters for mobile and high-end workstation users who need to attach multiple serial (RS-232) ports, a printer port, and USB peripherals to a single USB upstream connector. Cabling Edgeport Type A Type B The Edgeport/42 and Edgeport/421 operate as self-powered hubs, requiring a power supply to function. (For more information about hubs, see ―Understanding Hubs‖ on page 16.
Edgeport/416 The Edgeport/416 utilizes a standards-based USB bus for connectivity, unlike many serial card products which require additional external proprietary hardware to support the same number of devices. This Edgeport also supplies four USB ports, providing users with a built-in migration path as peripherals become USB-ready. The converters can be rack mounted and easily daisy-chained together. This Edgeport converter is available in two models: one with DB25 connectors and one with DB9 connectors.
Edgeport/2c The Edgeport/2c is an intelligent expansion module that connects to a PC or server running Windows 98, SE, CE, Me, NT 4.0, 2000 and Windows XP via the Universal Serial Bus (USB), providing high-speed serial connectivity. For more detailed information as well as the latest manual and technical updates, visit our website at www.digi.com.
Edgeport/21c, Edgeport/22c The Edgeport/21c and Edgeport/22c are compact, multi-connector converters for mobile and high-end workstation users who need to attach multiple serial (RS-232) ports, a printer port, and USB peripherals to a single USB upstream connector. Cabling Edgeport Type A These Edgeports operate as bus-powered hubs. For more information about hubs, see the section ―Understanding Hubs‖ on page 16.
Edgeport Driver Installation For Windows XP, Server 2003, Server 2008, and Vista Note: You must be logged into an account with administrator privileges before proceeding. Note: Please go to www.digi.com to download software for older Operating Systems. 1. Connect the USB cable. (Refer to the Table of Contents to locate the cabling instructions for your specific Edgeport model.
The System Status Light For All Edgeports except the Edgeport/1 Red This light signifies a loss of USB communication with the host. If the loss is due to unplugging the unit, when it is reconnected the light will blink red a few moments before turning green. Otherwise, the light indicates a problem with the drivers, which may need to be reinstalled. The red light will also blink during installation until the installation is complete. Amber This light signifies serial port activity on the Edgeport.
Mounting Diagrams For all Edgeport Products except Edgeport/416 Rack Mount Kit* Under-Shelf Mounting Bracket* For Edgeport/416* *Nuts, bolts, and screws are not included. Edgeport Installation Guide (90000403 Rev.
The Edgeport Utility Program For All Windows Operating Systems The Edgeport configuration utility program (edgeport.exe) allows you to manage the serial ports of your Edgeport product. Note that with Windows NT you must have administrative privileges in order to change the COM port settings. For more information, see the Support section at www.digi.com. General Tab The General tab in this utility allows you to do the following: Information - Check the manufacturing information pertaining to your device.
Configure - Reassign the physical port on your device to any available Windows COM port number from 1 to 255 and give your device a user friendly Device Name. This capability is particularly helpful if you have more than one device. Port Flags - Configure performance options and special functionality on a per-port basis. Edgeport Installation Guide (90000403 Rev.
Low Latency: (930 based Edgeport only) Normally the UART will interrupt when the receiver has been idle for 4 character times. (For example 4ms at 9600) As long as data is being received the UART will continue to buffer them until its internal FIFO is full (~56 bytes). This flag causes the Edgeport to poll the RX FIFO for received bytes. If any bytes are available they will be sent to the driver without any delay.
Test Ports - Perform a confidence test on the internal workings of the serial ports. Power Management – Turn on and off the power for HubPorts with USB PlusPower ports Edgeport Installation Guide (90000403 Rev.
Port Status – Provide the status of a selected (highlighted) serial port. The Poll Interval is the number of seconds between updates of this window. This is also the number of seconds between each entry in the log file. To create a log file, click the Start Logging button and enter a filename for the log file. This file will contain all of the information displayed in the Port Status window until the Stop Logging button is clicked. Refresh – Scan for ports. Note that NT 4.0 does not automatically scan.
Advanced Tab The Advanced tab allows you to do the following: Uninstall – Uninstall the drivers. Enable Event Logging – Place event messages in system event log. COM Port Assignment – Configure how COM ports will be assigned. The driver supports COM port number assignment in two ways: 1. Assign COM ports based on converter serial number. This is the default setting.
Understanding Hubs Hubs, critical components in the USB architecture, are wiring concentrators that enable the attachment of multiple devices, thus converting a single attachment point into multiple attachment points. USB architecture allows a cascaded multiple hub configuration with certain power limitations (explained later in this section). See figure 1.
Regulatory & Other Information © 2006 Digi, Digi International, the Digi logo, Edgeport, and Hubport are either trademarks or registered trademarks of Digi International, Inc. in the United States and/or other countries. All other trademarks are the property of their respective holders. Information in this documentation is subject to change without notice and does not represent a commitment on the part of Digi International.
Cet appareil numérique de la Classe B respecte toutes les exigences du Règlement sur le matériel brouiller du Canada. European Community - CE Mark Declaration of Conformity (DOC) According to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name: Digi International Product Name: Edgeport/42 Model Numbers: North America International 301-1042-01 301-2042-01 Product Name: Model Numbers: North America 301-1016-16 301-1000-10 Manufacturer’s Addr.
EN55022 Test Specification EN55022 Requirement Radiated Emissions — Class B Conducted Emissions CISPR 22 Class B Specification EN55024 Requirement EN61000-4-2 +2,+4 kV direct contact +2,+4 kV and +8kV air (insulated surfaces) +2,+4 kV(HCP&VCP) indirect EN 55024 Test Electrostatic Discharge Radiated Immunity EN61000-4-3 3 V/m, 80Mhz1000Mhz, amp mod 1kHz sine wave at 80% Electrical Fast Transient Burst EN61000-4-4 +0.5kV,+ 1kV (A/C) +0..5kV (I/O) Surge EN61000-4-5 +0.
China RoHS statement: The Table of Toxic and Hazardous Substances/Elements and their Content shall apply to any product covered by this manual and labeled with the following symbol: The Table of Toxic and Hazardous Substances/Elements and their Content as required by China’s Management Methods for the Control of Pollution from Electronic Information Products Part Name (部件名称) 301-1002-08 Lead (Pb) (铅) X Toxic and Hazardous Substances or Elements (有毒有害物质或元素) Hexavalent Polybrominated Polybrominated Cadmiu
Digi International 11001 Bren Road East Minnetonka, MN 55343 digi.info@digi.com www.digi.com Corporate Headquarters: 952-912-3444 877-912-3444 Fax: 952-912-4952 Digi Europe: +49-231-9747-0 Digi Hong Kong: +852-2833-1008 Digi North America: 877-912-3444 Edgeport Installation Guide (90000403 Rev.