User guide
set flow
116 Chapter 2  Command Descriptions 
set flow 
Device support This command is supported in all devices.
Purpose Configures or displays flow control options for the device server’s EIA-232 
serial ports. Several options related to the RTS toggle feature are hidden 
by default, and can be displayed by using the “show=rtstoggle” option.
Required 
permissions
The root user can configure flow control options. Normal users can display 
flow control options.
Syntax Configure flow control options 
set flow [aixon={on|off}] 
[altpin={on|off}] 
[cts={on|off}] 
[dcd={on|off}] 
[dsr={on|off}] 
[dtr={on|off}] 
[forcedcd={on|off}] 
[itoss={on|off}] 
[ixany={on|off}] 
[ixoff={on|off}] 
[ixon={on|off}] 
[pre-delay=milliseconds] 
[post-delay=milliseconds] 
[range=range] 
[ri={on|off|power}] 
[rts={on|off|toggle}] 
Display flow control options
set flow [range=range] 
Display hidden RTS toggle flow control options
set flow [range=range] show=rtstoggle
Options aixon={on|off}
Determines whether the auxiliary flow control characters defined on the 
"set keys" command are used for output flow control:
on
Auxiliary flow control characters are used.
off
Auxiliary flow control characters are not used.
The default is "off."