Product manual

XBee®/XBeePRO®RFModules‐802.15.4‐v1.xEx[2009.09.23]
©2009DigiInternatonal,Inc. 50
NT (Node Discover Time) Command
<Networking {Identification}> The NT command
is used to set the amount of time a base node will
wait for responses from other nodes when using
the ND (Node Discover) command. The NT value
is transmitted with the ND command.
Remote nodes will set up a random hold-off time
based on this time. The remotes will adjust this
time down by 250 ms to give each node the abil-
ity to respond before the base ends the command. Once the ND command has ended, any
response received on the base will be discarded.
P0 (PWM0 Configuration) Command
<I/O Setting {I/O Line Passing}> The P0 com-
mand is used to select/read the function for
PWM0 (Pulse Width Modulation output 0). This
command enables the option of translating
incoming data to a PWM so that the output can be
translated back into analog form.
With the IA (I/O Input Address) parameter cor-
rectly set, AD0 values can automatically be
passed to PWM0.
P1 (PWM1 Configuration) Command
<I/O Setting {I/O Line Passing}> The P1 com-
mand is used to select/read the function for
PWM1 (Pulse Width Modulation output 1). This
command enables the option of translating
incoming data to a PWM so that the output can be
translated back into analog form.
With the IA (I/O Input Address) parameter cor-
rectly set, AD1 values can automatically be
passed to PWM1.
PL (Power Level) Command
<RF Interfacing> The PL com-
mand is used to select and read
the power level at which the RF
module transmits conducted
power.
When operating in Europe,
XBee-PRO 802.15.4 modules
must operate at or below a
transmit power output level of
10dBm. Customers have 2
choices for transmitting at or
below 10dBm:
• Order the standard XBee-
PRO module and change
the PL command to "0"
(10dBm),
• Order the International variant of the XBee-PRO module, which has a maximum transmit out-
put power of 10dBm.
AT Command: ATNT
Parameter Range: 0x01 - 0xFC
[x 100 msec]
Default: 0x19 (2.5 decimal seconds)
Related Commands: ND (Node Discover)
Minimum Firmware Version Required: 1.xA0
AT Command: ATP0
The second character in the command is the
number zero (“0”), not the letter “O”.
Parameter Range: 0 - 2
Parameter Configuration
0 Disabled
1 RSSI
2PWM0 Output
Default Parameter Value: 1
AT Command: ATP1
Parameter Range: 0 - 2
Parameter Configuration
0 Disabled
1 RSSI
2PWM1 Output
Default Parameter Value: 0
Minimum Firmware Version Required: v1.xA0
AT Command: ATPL
Parameter Range: 0 - 4
Parameter XBee XBee-PRO
XBee-PRO
International
variant
0 -10 dBm 10 dBm PL=4: 10 dBm
1 -6 dBm 12 dBm PL=3: 8 dBm
2 -4 dBm 14 dBm PL=2: 2 dBm
3 -2 dBm 16 dBm PL=1: -3 dBm
4 0 dBm 18 dBm PL=0: -3 dBm
Default Parameter Value: 4