User`s guide

XBee Sensors
60
Associate/
Power LED:
Indicates power and the XBee Sensor’s ZigBee network association
status:
LED status Network association
On, solid green Not associated
On, blinking green Successfully joined
Reset/
Ident button:
Performs a reset and multiple functions for commissioning the
XBee Sensor in a ZigBee network.
Use a small non-conducive tool with a blunt end to press gently and hold
down button. Consecutive button presses must occur within one second of
each other to perform the desired action.
Button
press
Network
association
Action
Single Associated If XBee Sensor is asleep, wakes unit for 30 seconds.
Sends a Node Identification broadcast transmission.
All devices that receive this transmission will blink
their Associate LED rapidly for 1 second.
All API devices that receive this transmission will
send a Node Identification frame out their UART
(API ID 0x95).
Unassociated If XBee Sensor is asleep, wakes unit for 30 seconds.
Blinks a numeric error code on the Assc LED,
indicating the cause of join failure.
1 blink: Scan found no PANs.
2 blinks: Scan found no valid PANs based on cur-
rent SC and ID settings.
3 blinks: Valid Coordinator or Routers found, but
they are not allowing joining (NJ expired).
7 blinks: Node Joining attempt failed.
10 blinks: Coordinator Start attempt failed.
Two Associated Used only when network joining is permanently
enabled (by the XBee Module’s NJ setting being set to
anything other than OFF; in the gateway, this setting is
known as Allows Join Time=255). Temporarily allows
joining on the XBee Sensor and the entire ZigBee
network for 1 minute.
Four Associated/
Unassociated
XBee Sensor leaves PAN, if associated, and issues a
factory reset to restore default parameters. Default
PAN ID is 0x234.
Hold for
five
seconds
Associated/
Unassociated
Performs a hardware reset.