Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Contents CAUTION, 2 About this manual, 3 Unpacking, 3 Filter setup, 15 View setup, 16 Hex view, 16 Back to Baseband, 17 One level up/down, 17 Exit, 17 Introduction, 4 Installation, 5 Installing hardware and drivers, 5 Installing application software, 6 Uninstalling old programs, 6 Data Collector operation, 8 Features, 8 Main window, 9 Starting log session, 10 Stopping log session, 12 Opening old log session, 12 Saving log session, 12
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual CAUTION FCC Radio-Frequency Exposure Statement This equipment generates and radiates radio-frequency energy. In order to comply with FCC radio-frequency radiation exposure guidelines for an uncontrolled environment, this equipment has to be installed and operated while maintaining a minimum body-to-antenna distance of 20 cm. Users are not permitted to make changes or modify the system in any way.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual About this manual This installation and operation manual provides you with the information you need to make maximum use of Digianswer’s Bluetooth™ Protocol Analyser. The manual is structured as follows: Note: This product has been designed for development purposes and is not to be sold to or used by end users. • The Introduction provides basic information on what the Bluetooth Protocol Analyser is and how it works.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Introduction Digianswer’s Bluetooth Protocol Analyser is a development kit that allows you to view Bluetooth protocol data and carry out fast and effective analysis during the process of developing Bluetooth equipment.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Installation The installation procedure includes installing hardware, drivers, and software applications for the Bluetooth Protocol Analyser. In addition, Digianswer’s Bluetooth Software Suite will be installed. Note: If the Digianswer Bluetooth Demo Card or a previous version of the Bluetooth Software Suite is installed on your computer, you must uninstall this before you can install the Bluetooth Protocol Analyser.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Installing application software Uninstalling old programs Having connected the Bluetooth USB Protocol Analyser and installed the drivers, your are now ready to install the application software for the Bluetooth Protocol Analyser: the Data Collector and the Bluetooth Packet Analyser. At the same time you will be installing Digianswer’s Bluetooth Software Suite.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual 5. Enter the \windows\inf directory and delete the following files: To uninstall the drivers: 1. Enter System Properties / Device Manager. 2. Locate and remove the Digianswer Bluetooth Demo Card Controller and the Digianswer Bluetooth Ethernet Adapter. Dgahub.inf Dganet.inf Dgapcc.inf Dgahub.inf Dgausb.inf Drvdata.bin and Drvidx.bin 6. Enter the \windows\system32\drivers directory and delete the following files: 3. Click OK.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Data Collector operation Features The purpose of the Data Collector is, basically, to listen in on the Bluetooth piconet to which it is connected, and create a log containing all the baseband packets transmitted between the Bluetooth devices participating in the piconet.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual j File, Modules, and Help menus. The File menu contains Main window In this section, we will take a look at the Data Collector main window. In the following sections, we will go into detail with the various functions of the program. j k l an item for each of the functions that you can use the Data Collector for: Opening logged files, saving files, starting log sessions, stopping log session, and quitting the Data Collector.
Digianswer Bluetooth Protocol Analyser Starting log session Installation & Operation Manual We will now take a look at the three main items of this dialog box: Logging Mode, Hopping Mode, and Data Whitening. Logging Mode: Click this icon to open the Start new log session dialog box: Piconet Member Mode is to be used in connection with the Bluetooth Software Suite. When a log session is started, the Bluetooth Protocol Analyser logs all baseband packets sent from and received by your computer.
Digianswer Bluetooth Protocol Analyser • Sync to piconet using fake connection response: This mode can only be used during the connect phase, i.e. when the piconet master connects to a new slave. The Protocol Analyser pretends it is the slave unit chosen in the Select ... dialog box and obtains the master clock information by initiating a new connection as if it were that slave.
Digianswer Bluetooth Protocol Analyser Selecting Independent Mode also involves setting the number of seconds allowed to pass when there is no activity in the piconet. On timeout, the Bluetooth Protocol Analyser will inform you of the lack of activity. Note: When you use the Bluetooth Protocol Analyser in connection with the Bluetooth Software Suite, it has to be in piconet mode, i.e. working as a participant in a piconet. When the Bluetooth Protocol Analyser is in independent mode, i.e.
Digianswer Bluetooth Protocol Analyser Exit Click this icon to quit the Data Collector. Installation & Operation Manual Bluetooth Packet Analyser operation Features The purpose of the Bluetooth Packet Analyser is, basically, to analyse and display the contents of log files created by means of the Data Collector. The Bluetooth Packet Analyser can: • Analyse baseband packets and display ID, IQ, NULL, POLL, FHS, DMx, DHx, HVx, and DV Packets.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual j File, View, and Help menus. From the File menu you can Main window In this section we will take a look at the main window of the Bluetooth Packet Analyser. In the following sections, we will go into detail with the various functions of the program. j klm n open files, view the properties of the current log file, and quit the program.
Digianswer Bluetooth Protocol Analyser Opening a file Installation & Operation Manual which list of packets is selected. The following example shows the dialog box as it appears when selected from Baseband: This function – Load Log session from file – will open a dialog box that allows you to browse and open a log file. The Protocol Analyser features especially fast load of files of sizes up to the available physical and virtual memory limitations. Files exceeding that size will be loaded less fast.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual View setup Hex view For each of the tabs representing a list of packets – Baseband, LMP, L2CAP, RFCOMM, or SDP – you can select which elements should be displayed in the list view. This is done in the View Setup dialog box. In the example below, the following elements have been selected for Baseband: Index, Rx/Tx, and Packet Type. The main window only shows part of what a packet contains (except at the RFCOMM and SDP level).
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Back to Baseband Exit Click this icon to return to the list of baseband packets from any of the other lists of packets. Click this icon to quit the Bluetooth Packet Analyser. One level up/down When a packet is highlighted in the list view, you can navigate from one level of information to another by means of Enter (one level down) and Backspace (one level up). For instance, in Baseband, highlight an L2CAP packet, and press Enter.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Technical facts System requirements Hardware specifications • Computer with a 266 MHz or higher processor; Pentium II recommended • Microsoft Windows 95 or later operating system (excluding Windows NT) • • • • • 64 MB RAM Bluetooth radio specifications • Free hard-disk space required: Approx. 100 MB (depending on the amount of data logged) • Designed in accordance with the Bluetooth specification version 1.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Appendix A: Changes implemented since v1.0 The following is a list of the new features implemented in the Bluetooth Protocol Analyser version 1.1 (i.e. features not implemented in version 1.0, known as the ”Bluetooth Sniffer”): Data Collector • Three sync modes. • It is now possible to edit a selected master MAC address in the Start new session dialog box Master edit field.
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Appendix B: Packet format The following table shows the packet format of the Bluetooth Protocol Analyser. Each [xx] represents one byte. Byte position Name Description [01] [02] Sync word Protocol Analyser packet type [03] Packet counter (15-8) [04] [05] [06] [07] Packet counter (7-0) Total length (7-0) Total length (15-8) Status byte The Digianswer specified sync word for the Protocol Analyser packet is 0xFF.
Digianswer Bluetooth Protocol Analyser [08] [09] [10] [11] [12] Estimated clock (27-24) Estimated clock (23-16) Estimated clock (15-8) Estimated clock (7-0) Hop frequency [13] Header info: AM address (bit 2-0) Header info: Type (bit 3-0) Header info: FLOW (bit 0) Header info: ARQN (bit 0) Header info: SEQN (bit 0) Payload info: L_CH (bit 1-0) Payload info: FLOW (bit 0) Payload info: Length (bit 8) Payload info: Length (bit 7-0) 1st payload data byte 2nd payload data byte ... ... ...
Digianswer Bluetooth Protocol Analyser Installation & Operation Manual Appendix C: Regulatory statements General Japan This product complies with any mandatory product specification in any country where the product is sold. In addition, the product complies with the following. United States of America and Canada Tested To Comply With FCC Standards FOR HOME OR OFFICE USE. See FCC 47CFR part 15.19(b)(2). This device complies with part 15 of the FCC rules and with RSS-210 / RSS-139 of the Industry Canada.
Digianswer Bluetooth Protocol Analyser Appendix D: Digianswer contact information Skalhuse 5 DK-9240 Nibe Denmark Phone: +45 9671 0000 Fax: +45 9835 0052 E-mail: BluetoothPA@Digianswer.com Web site: www.digianswer.