User guide

SD10 - Getting Started
1-14
1.7 Audio Sync
The SD10 will operate at Sample Rates of either 48000Hz (48kHz) or 96000Hz (96kHz). By default, it is set to clock internally (as a
Master) at 48kHz. To switch the clock to 96kHz, open the Session Structure dialogue in the File menu and click on the appropri-
ate sample rate button at the top of the window.
Within a normal setup, the SD10 will usually remain as clock master. However, there are times when the SD10 needs to be
clocked externally. The Audio Sync panel allows you to control external synchronisation.
To access the Audio Sync Panel, touch the Setup Menu button, followed by Audio Sync. A panel similar to the below will open.
The SD10 will clock from the following sources : Word Clock, AES/EBU, MADI & Optocore (if fitted)
Note : When a valid clock is detected on an external sync input, the corresponding Green OK box will light, even if that input is not
selected as the clock source for the SD10.
Example External Clocking : Word Clock @ 48kHz