User guide

Chapter 6: Configuring Your Pro Tools System 59
Configuring 96i I/O Controls
To configure controls for a 96i I/O:
1 With the 96i I/O selected in the Peripherals
list, configure your I/O front panel meters for in-
put or output metering from the Meters pop-up.
2 Set input sensitivity by doing the following:
For Inputs 1–4, set the input trim slider to
match the output level of the connected in-
strument. Choices range from –12 dBV to
+4 dBu. If you do not know the output
level of the device, use the default input
trim level, then fine tune the input level
sensitivity.
For each input 5–16 being used, select
–8 dBV or +4 dBu as appropriate to best
match the output level of the connected in-
strument.
3 Set Output levels (select –10 dBV or +4 dBu).
4 Click Done.
You can select analog or digital input as sources
for 96i I/O channels 1–2. Only channels 1–2 can
access the S/PDIF inputs.
To select analog or digital input for channels 1-2:
1 Choose Setup > Hardware, and select 96i I/O in
the Peripherals list to display the 96i I/O win-
dow.
2 Click to set Ch 1–2 Input to Analog or S/PDIF,
as appropriate.
Configuring Legacy I/Os
Before you can configure a Legacy I/O, it must
first be initialized in Hardware Setup.
To initialize a Legacy I/O on a Pro Tools|HD
system:
1 Lower the volume of your output devices.
2 Start up your Pro Tools system (see “Starting
Up or Shutting Down Your System” on page 43).
3 In Pro Tools, choose Setup > Hardware.
4 From the Peripherals list, choose the primary
audio interface (the interface to which your Leg-
acy I/O is connected).
5 In the Main page of the Hardware Setup dia-
log, select the Legacy I/O option under Port Set-
tings.
6 In the Peripherals list, No Interface is listed
twice, directly below the primary audio inter-
face. Click the first No Interface. An Interface
pop-menu appears in the Hardware Setup dia-
log, listing supported I/O choices.
For detailed information about configuring
96i I/O, see the 96i I/O Guide.
Hardware Setup for 96i I/O
The 96i I/O only supports analog and digi-
tal switching for channels 1–2, and only
from within the Hardware Setup and I/O
Setup dialogs. The 96i I/O does not support
path remapping within I/O Setup.
Before turning on your Legacy I/O, make
sure to lower the volume of your output de-
vices. Very loud digital noise may be emit-
ted before the Legacy I/O is initialized.