SPECIFICATIONS
Configuration
Size 1U 19” rack : 43.9 x 482.6 x 297.1 mm
Power supply
100 - 240 VAC, 47-63 Hz
switching-mode, automatic voltage detection
WARNING: Do not open the power supply module. It contains hazardous
voltages.
There are no user-serviceable parts inside
Temp / humidity
(non-condensing)
Operating:
Storage:
0 °C - 50 °C / 0% - 95%
-5 °C – 70 °C / 0% - 95%
Power consumption ES881/ES1241/ES16161 : 0.23 A at 100 V, 0.125 A at 240 V
Net weight
3,1 kg (6.85 lbs)
Entrées/sorties
EtherSound ES881 EtherSound ES1241 EtherSound ES16161
Digital audio
AES/EBU 3
4 stereo inputs
4 stereo outputs
2 stereo inputs
6 stereo outputs
8 stereo inputs
8 stereo outputs
With one hw sample rate converter per input,
conversion ratio 1:3 to 3:1, up to 96 kHz
Impedance
110 Ω 110 Ω 110 Ω
Sampling frequencies
available
48 kHz or 44.1 kHz
Connectivity
EtherSound ES881 EtherSound ES1241 EtherSound ES16161
Digital audio 4 female XLR-3 and
4 male XLR-3
2 female XLR-3 and
6 male XLR-3
4 female Sub-D 25
EtherSound 2 female EtherCon RJ45 compatible (connections “IN”/“OUT”)
GPIO 4 optocoupled inputs and 4 relay outputs on 8-point terminal blocks
Serial ports 1 RS232 on DB9
Synchronization
Clock source
If ‘Primary Master in an EtherSound network:
Internal, Word Clock or on ‘AES IN 1’ input
If not ‘Primary Master’: EtherSound network, Word Clock or on ‘AES IN 1’
input (synchronized on the ‘Primary Master’ clock)