Datasheet

2010 Microchip Technology Inc. DS39935C-page 141
ENC424J600/624J600
17.0 ELECTRICAL CHARACTERISTICS
Absolute Maximum Ratings
Storage temperature ...............................................................................................................................-65°C to +150°C
Ambient temperature under bias.............................................................................................-40°C to +85°C (Industrial)
Voltage on V
DD, VDDOSC, VDDPLL, VDDRX and VDDTX, with respect to VSS ................................................. -0.3V to 4.0V
Voltage on any digital pin, with respect to V
SS............................................................................................. -0.3V to 6.0V
Voltage on OSC1 and RBIAS analog pins, with respect to V
SS.........................................................-0.3V to VDD + 0.3V
Voltage on TPIN+/- and TPOUT+/-, with respect to V
SS.............................................................................. -0.3V to 5.0V
Voltage on V
CAP, with respect to all VSS pins (Note 1)................................................................................ -0.3V to 2.0V
ESD protection on all pins.......................................................................................................................................... 2 kV
Current sourced or sunk by any digital output pin...................................................................................................25 mA
Current out of all V
SS pins.....................................................................................................................................420 mA
Current into all V
DD pins........................................................................................................................................300 mA
Note 1: VCAP is not designed to supply an external load. No external voltage should be applied to this pin.
Notice: Stresses above those listed under “Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only and functional operation of the device at those or any other conditions above those indicated in
the operational listings of this specification is not implied. Exposure to maximum rating conditions for extended periods
may affect device reliability.