Analog Inputs and V
Ref
The PmodAD2 allows for up to 4 analog inputs
VIN1 VIN4. In order to use the input VIN4
the jumper JP1 must be set to V4.
In the configuration register there is a bit
REF_SEL that when enabled allows a different
voltage other than the supply voltage to be
used as the reference. If REF_SEL is enabled,
V
Ref
is 2.048V from the on board voltage
reference generator if JP1 is set to REF, if JP1
is set to V4 V
Ref
is the voltage at input VIN4.
Connector J2 Analog Input
Pin
Signal
Description
1
VIN1
Analog Input 1
2
VIN2
Analog Input 2
3
VIN3
Analog Input 3
4
VIN4
Analog Input 4
5
GND
Power Supply Ground
6
VCC
Power Supply (3.3V)