Datasheet

PmodACL2Reference Manual
Copyright Digilent, Inc. All rights reserved.
Other product and company names mentioned may be trademarks of their respective owners.
Page 2 of 3
clock edge. Because the address pointer auto-increments to the next address byte, it is possible to read multiple
bytes consecutively by continuing to pulse the Serial Clock line. An example set of commands to read from the y-
axis register is given below:
Note: Each SX bit is the same value as the most significant bit of the y-axis data.
To read from the FIFO buffer, a command byte to write to a data register (0x0A) must first be sent so that we can
configure the FIFO Control register (address 0x28) to indicate that we want the FIFO buffer to store data. After the
ADXL362 has been configured to use the FIFO buffer, a command byte to read from the FIFO buffer (0x0D) must
first be sent, then followed by pairs of data bytes containing which axis is being measured as well as the
acceleration data. An example set of commands to read from the FIFO buffer is given below:
Note: Each SX bit is the same value as the most significant bit of the y-axis data. b15 and b14 represent which axis the incoming data represents.
2.1 Pinout Description Table
Pinout Table of the PmodACL2
Connector J1
Connector J2
Pin
Signal
Description
Pin
Signal
Description
Pin
Signal
Description
1
~CS
Chip select
7
INT2
Interrupt Two
1
INT1
Interrupt One
2
MOSI
Master Out Slave
In
8
INT1
Interrupt One
2
G
Power Supply
Ground
3
MISO
Master In Slave
Out
9
NC
Not connected
Connector J3
4
SCLK
Serial clock
10
NC
Not connected
Pin
Signal
Description
5
GND
Power supply
ground
11
GND
Power supply
ground
1
INT2
Interrupt Two
6
VCC
Power supply
(3.3V)
12
VCC
Power supply
(3.3V)
2
G
Power Supply
Ground
Command Read
First Y-axis Address
0
0
0
0
1
0
1
1
0
0
0
0
1
0
1
0
LSB Byte of Y-axis Data
MSB Byte of Y-axis Data
b7
b6
b5
b4
b3
b2
b1
LSB
SX
SX
SX
SX
MSB
b10
b9
b8
Command Read
FIFO Control Register Address
Command FIFO Read
0
0
0
0
1
0
1
0
0
0
1
1
0
0
0
0
0
0
0
0
1
1
0
1
LSB Byte of Axis Data
MSB Byte of Axis Data
b7
b6
b5
b4
b3
b2
b1
LSB
b15
b14
SX
SX
MSB
b10
b9
b8