Datasheet

SSM2518 Data Sheet
Rev. A | Page 34 of 48
FAULT CONTROL 1 REGISTER
Address: 0x08, Reset: 0x0C, Name: Fault_Control_1
Table 21. Bit Descriptions for Fault_Control_1
Bits Bit Name Settings Description Reset Access
7 OC_L Left Channel Overcurrent Fault. Read only. 0x0 R
0 Normal operation
1 Left channel overcurrent fault
6 OC_R Right Channel Overcurrent Fault. Read only. 0x0 R
0 Normal operation
1 Right channel overcurrent fault
5 OT Overtemperature Fault Status. Read only. 0x0 R
0 Normal operation
1 Overtemperature fault
4 MRCV Manual Fault Recovery. Available only when ARCV = 11. Write only. 0x0 W
0 Normal operation
1 When written, attempt a manual fault recovery
[3:2] MAX_AR Maximum Fault Recovery Attempts. 0x3 RW
00 One attempt
01 Three attempts
10 Seven attempts
11 Unlimited attempts
[1:0] ARCV Automatic Fault Recovery Selection. 0x0 RW
00 Automatically recover from overtemperature and overcurrent faults
01 Automatically recover from overtemperature fault only
10 Automatically recover from overcurrent faults only
11 No automatic recovery