Datasheet
SSM2518 Data Sheet
Rev. A | Page 44 of 48
DRC CONTROL 7 REGISTER
Address: 0x10, Reset: 0x26, Name: DRC_Control_7
Table 29. Bit Descriptions for DRC_Control_7
Bits Bit Name Settings Description Reset Access
[7:4] HDT_NOR
DRC Normal Operation Hold Time. Used to prevent the gain curve
calculation from increasing too quickly.
0x2 RW
0000 0 ms
0001 0.67 ms
0010 1.33 ms
0011 2.67 ms
0100 5.33 ms
0101 10.66 ms
0110 21.32 ms
0111 42.64 ms
1000 85.28 ms
1001 170.56 ms
1010 341.12 ms
1011 682.24 ms
1100 1.364 sec
1101 Reserved
1110 Reserved
1111 Reserved
[3:0] HDT_NG
DRC Noise Gate Hold Time. Used to prevent the DRC from entering noise
gate too quickly.
0x6 RW
0000 0 ms
0001 0.67 ms
0010 1.33 ms
0011 2.67 ms
0100 5.33 ms
0101 10.66 ms
0110 21.32 ms
0111 42.64 ms
1000 85.28 ms
1001 170.56 ms