Datasheet

2009-2016 Microchip Technology Inc. DS60001156J-page 377
PIC32MX5XX/6XX/7XX
FIGURE 32-11: SPIx MODULE MASTER MODE (CKE = 1) TIMING CHARACTERISTICS
TABLE 32-29: SPIx MODULE MASTER MODE (CKE = 1) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A
+85°C for Industrial
-40°C T
A
+105°C for V-Temp
Param.
No.
Symbol Characteristics
(1)
Min. Typ.
(2)
Max. Units Conditions
SP10 T
SC
L SCKx Output Low Time
(3)
T
SCK
/2 ns
SP11 T
SC
H SCKx Output High Time
(3)
T
SCK
/2 ns
SP20 T
SC
F SCKx Output Fall Time
(4)
ns See parameter DO32
SP21 T
SC
R SCKx Output Rise Time
(4)
ns See parameter DO31
SP30 T
DO
F SDOx Data Output Fall Time
(4)
ns See parameter DO32
SP31 T
DO
R SDOx Data Output Rise Time
(4)
ns See parameter DO31
SP35 T
SC
H2
DO
V,
T
SC
L2
DO
V
SDOx Data Output Valid after
SCKx Edge
——15nsV
DD
> 2.7V
——20nsV
DD
< 2.7V
SP36 T
DO
V2
SC
,
T
DO
V2
SC
L
SDOx Data Output Setup to
First SCKx Edge
15 ns
SP40 T
DI
V2
SC
H,
T
DI
V2
SC
L
Setup Time of SDIx Data Input to
SCKx Edge
15 ns V
DD
> 2.7V
20 ns V
DD
< 2.7V
SP41 T
SC
H2
DI
L,
T
SC
L2
DI
L
Hold Time of SDIx Data Input
to SCKx Edge
15 ns V
DD
> 2.7V
20 ns V
DD
< 2.7V
Note 1:
These parameters are characterized, but not tested in manufacturing.
2:
Data in “Typical” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.
3:
The minimum clock period for SCKx is 40 ns. Therefore, the clock generated in Master mode must not
violate this specification.
4:
Assumes 50 pF load on all SPIx pins.
SCK
X
(CKP = 0)
SCK
X
(CKP = 1)
SDO
X
SDI
X
SP36
SP30,SP31
SP35
MSb
Bit 14 - - - - - -1
LSb In
Bit 14 - - - -1
LSb
Note:
Refer to Figure 32-1 for load conditions.
SP11 SP10
SP21
SP20
SP40
SP41
SP20
SP21
MSb In