Datasheet

18
ADCS7476
,
ADCS7477
,
ADCS7478
SNAS192G APRIL 2003REVISED MAY 2016
www.ti.com
Product Folder Links: ADCS7476 ADCS7477 ADCS7478
Submit Documentation Feedback Copyright © 2003–2016, Texas Instruments Incorporated
Device Functional Modes (continued)
Figure 27. ADCS7476/77 Ideal Transfer Characteristic
Figure 28. ADCS7478 Ideal Transfer Characteristic
7.4.2 Power-Up Timing
The ADCS747x typically requires 1 µs to power up, either after first applying V
DD
, or after returning to normal
mode from shutdown mode. This corresponds to one dummy conversion for any SCLK frequency within the
specifications in this document. After this first dummy conversion, the ADCS747x performs conversions properly.
NOTE
The t
QUIET
time must still be included between the first dummy conversion and the second
valid conversion.