User manual
1300 Henley Court
Pullman, WA 99163
509.334.6306
www.digilentinc.com
PmodDPG1 Reference Manual
Revised August 10, 2016
This manual applies to the PmodDPG1 Rev. A
DOC#: 510-333
Copyright Digilent, Inc. All rights reserved.
Other product and company names mentioned may be trademarks of their respective owners.
Page 1 of 4
Overview
The Digilent PmodDPG1 (Revision A) is a differential gauge pressure module. With NXP's MP3V5010DP
piezoresistive transducer and Texas Instrument's ADCS7476 12-bit Analog-to-Digital Converter, you can detect
when a change in pressure between the two ports occurs and send digital information to your system board.
1 Functional Description
The PmodDPG1 is designed to detect a gauge pressure ranging from 0 kPa to 10 kPa with a piezoresistive
transducer and use an embedded 12-bit ADC to provide the user with a serial stream of data representative of the
measured pressure.
The PmodDPG1.
Differential gauge pressure transducer
12-bit ADC
0 to 10 kPa differential pressure range
Temperature compensated and calibrated
6-pin Pmod connector with SPI interface
Follows Digilent Pmod Interface
Specification Type 2
Features include: