User manual

Table Of Contents
Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1048
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Register FTMITATBCTR2 Details
Register (ftm) FTMITATBCTR1
Register FTMITATBCTR1 Details
Register (ftm) FTMITATBCTR0
Absolute Address 0xF880BEF0
Width 2 bits
Access Type ro
Reset Value 0x00000001
Description ATB Control Integration Test Register 2
Field Name Bits Type Reset Value Description
AFVALID 1 ro 0x0 Read the current value of the AFVALIDM input
ATREADY 0 ro 0x1 Read the current value of the ATREADYM input
Name FTMITATBCTR1
Relative Address 0x00000EF4
Absolute Address 0xF880BEF4
Width 7 bits
Access Type rw
Reset Value 0x00000000
Description ATB Control Integration Test Register 1
Field Name Bits Type Reset Value Description
ATID_test 6:0 rw 0x0 When ITEN is 1, this value determines the ATID
output
Name FTMITATBCTR0
Relative Address 0x00000EF8
Absolute Address 0xF880BEF8
Width 10 bits
Access Type wo
Reset Value 0x00000000
Description ATB Control Integration Test Register 0