User manual

Table Of Contents
Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1127
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Register (tpiu) FormatSyncCount
Register FormatSyncCount Details
Register (tpiu) EXTCTLIn
FOnMan 6 rw 0x0 Manually generate a flush of the system. Setting
this bit causes a flush to be generated. This is
cleared when this flush has been serviced.
FOnTrig 5 rw 0x0 Generate a flush using Trigger event.
Set this bit to cause a flush of data in the system
when a Trigger Event occurs.
FOnFlIn 4 rw 0x0 Generate flush using the FLUSHIN interface. Set
this bit to enable use of the FLUSHIN connection.
reserved 3:2 ro 0x0 Reserved
EnFCont 1 rw 0x0 Continuous Formatting, no TRACECTL. Embed
in trigger packets and indicate null cycles using
Sync packets. Can only be changed when
FtStopped is HIGH.
EnFTC 0 rw 0x0 Enable Formatting. Do not embed Triggers into
the formatted stream. Trace disable cycles and
triggers are indicated by TRACECTL, where
fitted. Can only be changed when FtStopped is
HIGH.
Name FormatSyncCount
Relative Address 0x00000308
Absolute Address 0xF8803308
Width 12 bits
Access Type rw
Reset Value 0x00000040
Description Formatter Synchronization Counter Register
Field Name Bits Type Reset Value Description
Field Name Bits Type Reset Value Description
CycCount 11:0 rw 0x40 12-bit counter value to indicate the number of
complete frames between full synchronization
packets.
Name EXTCTLIn
Relative Address 0x00000400
Absolute Address 0xF8803400