User manual

Table Of Contents
Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1542
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Register Block_Size_Block_Count Details
Field Name Bits Type Reset Value Description
Blocks_Count_for_Cur
rent_Transfer
31:16 rw 0x0 This register is enabled when Block Count Enable
in the Transfer
Mode register is set to 1 and is valid only for
multiple block transfers. The HC decrements the
block count after each block transfer and stops
when the count reaches zero. It can be accessed
only if no transaction is
executing (i.e. after a transaction has stopped).
Read operations
during transfer return an invalid value and write
operations shall
be ignored. When saving transfer context as a
result of Suspend command, the number of blocks
yet to be transferred can be determined
by reading this register. When restoring transfer
context prior to
issuing a Resume command, the HD shall restore
the previously
save block count.
0000h - Stop Count
0001h - 1 block
0002h - 2 blocks
--- ---
FFFFh - 65535 blocks
reserved 15 ro 0x0 Reserved