User manual

Table Of Contents
Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1574
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Register (sdio) ADMA_error_status
Register ADMA_error_status Details
When ADMA Error Interrupt occurs, the ADMA Error States field in this register holds the ADMA state
and the ADMA System Address Register holds the address around the error descriptor.
Force_Event_for_Com
mand_Timeout_Error
16 wo 0x0 Force Event for Command Timeout Error
1 - Interrupt is generated
0 - No interrupt
reserved 15:8 ro 0x0 Reserved
Force_Event_for_com
mand_not_issued_by_
Auto_CMD12_Error
7 wo 0x0 1 - Interrupt is generated
0 - no interrupt
reserved 6:5 ro 0x0 Reserved
Force_Event_for_Auto
_CMD12_Index_Error
4 wo 0x0 1 - Interrupt is generated
0 - no interrupt
Force_Event_for_Auto
_CMD12_End_bit_Erro
r
3 wo 0x0 1 - Interrupt is generated
0 - no interrupt
Force_Event_for_Auto
_CMD12_CRC_Error
2 wo 0x0 1 - Interrupt is generated
0 - no interrupt
Force_Event_for_Auto
_CMD12_timeout_Erro
r
1 wo 0x0 1 - Interrupt is generated
0 - no interrupt
Force_Event_for_Auto
_CMD12_NOT_Execut
ed
0 wo 0x0 1 - Interrupt is generated
0 - no interrupt
Name ADMA_error_status
Relative Address 0x00000054
Absolute Address sd0: 0xE0100054
sd1: 0xE0101054
Width 3 bits
Access Type mixed
Reset Value 0x00000000
Description ADMA error status register
Field Name Bits Type Reset Value Description