Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1613
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Register FPGA1_THR_STA Details
Register (slcr) FPGA2_CLK_CTRL
Register FPGA2_CLK_CTRL Details
Description PL Clock 1 Throttle Status control
Field Name Bits Type Reset Value Description
reserved 31:17 ro 0x0 Reserved. Writes are ignored, read data is zero.
RUNNING 16 ro 0x1 Current running status of FPGA clock output:
0: Clock is stopped or in normal mode (OK to
change configuration).
1: Clock is running in debug mode (Keep
configuration static).
CURR_VAL 15:0 ro 0x0 Current clock throttle counter value, which
indicates the number of clock pulses output so far
(only accurate when halted).
Name FPGA2_CLK_CTRL
Relative Address 0x00000190
Absolute Address 0xF8000190
Width 32 bits
Access Type rw
Reset Value 0x00101800
Description PL Clock 2 output control
Field Name Bits Type Reset Value Description
reserved 31:26 rw 0x0 Reserved. Writes are ignored, read data is zero.
DIVISOR1 25:20 rw 0x1 Provides the divisor used to divide the source
clock to generate the required generated clock
frequency. Second cascade divide
reserved 19:14 rw 0x0 Reserved. Writes are ignored, read data is zero.
DIVISOR0 13:8 rw 0x18 Provides the divisor used to divide the source
clock to generate the required generated clock
frequency. First cascade divider.
reserved 7:6 rw 0x0 Reserved. Writes are ignored, read data is zero.
SRCSEL 5:4 rw 0x0 Select the source used to generate the clock:
0x: Source for generated clock is IO PLL.
10: Source for generated clock is ARM PLL.
11: Source for generated clock is DDR PLL.
reserved 3:0 rw 0x0 Reserved. Writes are ignored, read data is zero.