Zynq-7000 AP SoC Technical Reference Manual www.xilinx.com 1752
UG585 (v1.11) September 27, 2016
Appendix B: Register Details
Field Name Bits Type Reset Value Description
ecc_int
(ECC_VALUE_INT)
31 ro 0x0 Interrupt flag for this value
ecc_valid
(ECC_VALUE_VALID)
30 ro 0x0 Indicate if this value is valid
ecc_read
(ECC_VALUE_READ)
29 ro 0x0 Indicate if the ECC value has been read from
memory
ecc_fail
(ECC_VALUE_FAIL)
28 ro 0x0 Indicate if this value has failed
ecc_correct
(ECC_VALUE_CORRE
CT)
27 ro 0x0 Indicate if this block is correctable
reserved 26:24 ro 0x0 Reserved, read undefined
ecc_value
(ECC_VALUE)
23:0 ro 0x0 ECC value of check result for block, depending on
ECC configuration