Although the default power-up configuration of the PHY might be enough in most applications, the MDIO bus is
available for management. The RTL8211E-VL is assigned the 5-bit address 00001 on the MDIO bus. With simple
register read and write commands, status information can be read out or configuration changed. The Realtek PHY
follows industry-standard register map for basic configuration.
The RGMII specification calls for the receive (RXC) and transmit clock (TXC) to be delayed relative to the data
signals (RXD[0:3], RXCTL and TXD[0:3], TXCTL). Xilinx PCB guidelines also require this delay to be added. The
RTL8211E-VL is capable of inserting a 2ns delay on both the TXC and RXC so that board traces do not need to be
made longer.
The PHY is clocked from the same 50 MHz oscillator that clocks the Zynq PS. The parasitic capacitance of the two
loads is low enough to be driven from a single source.
On an Ethernet network each node needs a unique MAC address. To this end, the one-time-programmable (OTP)
region of the Quad-SPI flash has been programmed at the factory with a 48-bit globally unique EUI-48/64™
compatible identifier. The OTP address range [0x20;0x25] contains the identifier with the first byte in transmission
byte order being at the lowest address. Refer to the Flash memory datasheet for information on how to access the
OTP regions. When using the PYNQ software, this is automatically handled in the boot-loader, and the Linux
system is automatically configured to use this unique MAC address.
For more information on using the Gigabit Ethernet MAC, refer to the Zynq Technical Reference manual.
10 HDMI
The PYNQ-Z1 contains two unbuffered HDMI ports: one source port J11 (output), and one sink port J10 (input).
Both ports use HDMI type-A receptacles with the data and clock signals terminated and connected directly to the
Zynq PL.
Both HDMI and DVI systems use the same TMDS signaling standard, directly supported by Zynq PL's user I/O
infrastructure. Also, HDMI sources are backward compatible with DVI sinks, and vice versa. Thus, simple passive
adaptors (available at most electronics stores) can be used to drive a DVI monitor or accept a DVI input. The HDMI
receptacle only includes digital signals, so only DVI-D mode is possible.
The 19-pin HDMI connectors include three differential data channels, one differential clock channel
five GND connections, a one-wire Consumer Electronics Control (CEC) bus, a two-wire Display Data Channel (DDC)
bus that is essentially an I2C bus, a Hot Plug Detect (HPD) signal, a 5V signal capable of delivering up to 50mA, and
one reserved (RES) pin. All non-power signals are wired to the Zynq PL with the exception of RES.
Pin/Signal
J11 (source)
J10 (sink)
Description
FPGA pin
Description
FPGA pin
D[2]_P,
D[2]_N
Data output
J18, H18
Data input
N20, P20
D[1]_P,
D[1]_N
Data output
K19, J19
Data input
T20, U20
D[0]_P,
D[0]_N
Data output
K17, K18
Data input
V20,
W20
CLK_P, CLK_N
Clock output
L16, L17
Clock input
N18, P19
CEC
Consumer Electronics Control
bidirectional
G15
Consumer Electronics Control
bidirectional
H17