User guide

Extending the SC9000 security console with a Digimax 210 thermostat.
If the console has not received any more messages from the thermostat, the LCD display will read
[PROBLEM ZONE X]
Programming the “differential temperature” on the console
The thermostat needs to be registered with the SC9000 to be able to view the Setback settings in the
OPTIONS menu (7).
1. To access the menu, press the menu Ĺ or menu Ļ button. The display will now read [ENTER PIN]
2. Enter your 4-digit PIN code (factory setting 0000.). For every digit, an asterisk (*) will appear on the
display.
3. If the PIN code has been entered correctly, the word INSTALL will appear on the display.
4. Press OK.
5. Use the buttons menu Ĺ/Ļҏ to scroll to menu item 7: [OPTIONS] Press OK to select this item. You can
also go directly to this item by pressing the 7 on the keyboard.
6. Use the buttons menu Ĺ/Ļҏ to scroll to menu item SETBACK. Press OK to select this menu item.
7. The display will now read SETBACK x DEG C. Enter the differential temperature. This can be set from
01 to 09 degrees. Press OK. The display will now read the new differential temperature.
Activating the “differential temperature” remotely
If the security console SC9000 is in “Arm Away” mode, you can use your phone to choose to activate the
temperature or not:
Make sure the dial-in function is activated (menu [OPTIONS/ANSWER TYPE])
1. Ring the security console from a land line or mobile phone.
2. The security console will respond to your call with “Please enter pin”.
3. Enter your PIN code via the buttons on your phone (standard setting is 0000).
4. The security console will respond to a correctly entered PIN code with “PIN accepted” (when entering
an incorrect PIN code you will hear ”ERROR”).
5. Press “88#” on your phone to activate the differential temperature. You will hear “Thermostat set back”
as a confirmation.
6. The “differential temperature” is now activated (the differential temperature is deducted from the comfort
setting).
To deactivate the “differential temperature”
Make sure the dial-in function is activated (menu [OPTIONS/ANSWER TYPE] ).
1. Ring the security console from a land line or mobile phone.
2. The security console will respond to your call with “Please enter pin”.
3. Enter your PIN code via the buttons on your phone (standard setting is 0000).
4. The security console will respond to a correctly entered PIN code with “PIN accepted” (when entering
an incorrect PIN code you will hear ”ERROR”).
5. Press “88*” on your phone to deactivate the differential temperature. You will hear “Thermostat normal”
as a confirmation.
6. The “differential temperature” is now deactivated (the differential temperature is no longer deducted
from the comfort setting).