Instruction manual
Speed Dome Camera Instruction Manual 17/49
Video
z Use BNC coaxial cable only.
Alarm Input
If you want to use Alarm Input, the types of sensors must be selected in OSD menu. The
sensor types are divided into Normal Open and Normal Close. If wrong sensor types are
selected, alarms should be activated reversely to sensor inputs.
~ Normal Open Output Voltage is high state when sensor is activated
~ Normal Close Output Voltage is high state when sensor is not activated
Relay Output
Internal
OUT 1
AC or DC
LOAD
The maximum loads are as follows.
Power Type DC Power AC Power
Maximum Load MAX. DC 24V, 1A MAX. AC 125V, 0.5A
INSTALLATION
2
IN COM
IN 1-
IN 3-
Sensor 1
Sensor 3
V+