Instruction manual
2. Installation and Connection
2.5 Setting Dome Camera
The device can communicate with external switching devices such as multiplexers or DVR’s by
setting the Rotary switch and Dip switch. Refer to tables below for setting the dome camera ID
and protocol selection. Total length of the cable for communication should not exceed 1km.
2.5.1 Setting the address (ID) of dome camera
To prevent wrong operation and malfunction, each dome camera has a unique address (ID).
The default setting is 0[ID001]
.
Dome Camera ID Setting (Rotary Switch, SW301, SW302)
X16 X1
SW301 SW302
2.5.2 Setting the protocol of dome camera
Dome Camera Protocol Setting (Dip Switch, SW303)
No1 No2 Protocol
Off Off Pelco-D/Pelco-P
Dome Camera Baud Rate Setting (Dip Switch, SW303)
No3 No4 Baud Rate(bps)
Off Off 2400
Off On 4800
On Off 9600
On On 38400
Dome Camera Termination Setting Off/On (NO5, Dip Switch, SW303)
12
SW302
SW301
SW303
The value of rotary switches is in hexadecimal. For example, if SW301 = A and SW302 = F then
the ID = 175(AF).