Installation manual

DGP2-641R LCD Keypad Module 15n
external power supply may correct the situation.
1. From Normal Mode press and hold the [0] key.
2. Enter the [
INSTALLER CODE] (by default 000000).
3. Press [
ACC].
The voltage may drop during the control panel battery test.
5.0 ACCESS CONTROL OPTIONS
5.1 Assigning Doors To Partitions
SECTION [002]: OPTIONS [1] TO [8]
Although the keypad can be programmed to display the status of
various partitions, the Access Control door can be assigned to one or
more partition(s) in the alarm system. This means that the actions
performed with the Access Control Card will be directly linked to the
partition(s) assigned to that door. For example, the keypad is assigned
to all eight partitions (see section 4.1 on page 10), but the door is
assigned to Partition 2. When the user presents the Access Control
Card to the door's reader to arm the partition, only Partition 2 will arm.
Option [1] ON = Door assigned to Partition 1(default)
Option [2] ON = Door assigned to Partition 2
Option [3] ON = Door assigned to Partition 3
Option [4] ON = Door assigned to Partition 4
Option [5] ON = Door assigned to Partition 5 (DGP-NE96 only)
Option [6] ON = Door assigned to Partition 6 (DGP-NE96 only)
Option [7] ON = Door assigned to Partition 7 (DGP-NE96 only)
Option [8] ON = Door assigned to Partition 8 (DGP-NE96 only)
OFF = Access Control Cards will not be able to arm and/or
disarm partitions from the door's reader