Installation manual

DGP2-641R LCD Keypad Module 19n
5.3.1 Door Left Open Access Alarm
S
ECTION [006]: OPTION [2]
When an Access Control door is opened after an Access Granted
or a Request for Exit, an Access Alarm can be generated if it is
not closed within a certain period of time (see section 5.3.2 on
page 19). When the Door Left Open Alarm is disabled, the
following sections are also disabled:
Option [2] OFF = Door Left Open Alarm won’t be generated
(default)
Option [2] ON = Door Left Open Alarm is enabled
5.3.2 Door Left Open Interval Before Access Alarm
S
ECTION [010]
The Door Left Open Interval is the time that a door can remain
open after an Access Granted or a Request for Exit without
generating an Access Alarm. Enter any value between 001 and
255 to determine the number of seconds the door may remain
open before the Access Alarm is triggered. Default = 60 secs.
5.3.3 Door Left Open Pre-Alarm
S
ECTION [004]: OPTION [3]
If an Access Control door is programmed with a Door Left Open
Interval (see section 5.3.2 above), the Pre-Alarm will cause the
Section
[004] Option [3] Door Left Open Pre-alarm
Option [5] Door Left Open Alarm
Option [6] Door Left Open Alarm follows
[010] Door Left Open Interval
[011] Door Left Open Pre-alarm Timer
[012] Beep Timer for Door Left Open Alarm
DGP2641R_ei00.fm Page 19 Thursday, July 22, 2004 4:16 PM