Installation manual

Digiplex/DigiplexNE LCD Keypad 15n
Option [2] OFF= Will not display Exit Delay timer (default).
Option [2] ON = LCD screen will display Exit Delay timer.
4.4 DISPLAY ENTRY DELAY TIMER
SECTION [003]: OPTION [3]
Based on the user's needs, an Entry Delay Timer will be
programmed to provide the user time to enter their User Access
Code before the alarm is triggered. The Entry Delay Timer's
countdown can be displayed on the LCD screen.
Option [3] OFF= Will not display the Entry Delay Timer (default).
Option [3] ON = LCD screen will display Entry Delay Timer.
4.5 CONFIDENTIAL MODE
SECTION [003]: OPTIONS [4] AND [5]
If the Confidential Mode is enabled and no actions are performed on
the keypad for a period of time, the LCD screen will appear as shown
in Figure 6 (page 16) and the “AC” and “STATUS” LED will be off until
either a button is pressed or an access code is entered. The period of
time in which no action is performed is defined by the Confidential
Mode Timer (005-255 seconds; refer to section 4.6 on page 16).
Confidential Mode is activated by enabling option [4]. Option [5]
regulates whether the LCD screen will be activated at the touch of a
button or only when an access code is entered.
Once the LCD screen is activated (by code or button), Normal Mode
will appear and display the date and time as shown in Figure 6 on
page 16. The status of the areas, the open zones for every area the
keypad is assigned, the Alarm Memory Display (if necessary) and the
Trouble Display (if necessary. See Digiplex or DigiplexNE User
Manual) will also scroll on the LCD screen. By default, options [4]
and [5] are OFF.