Specifications
USB Usage
ADDvantage-32 PLUS ● AC to DC Power Converter
11-19
A calibration file that has been saved using the ADDAPT program can be loaded by the
drive via the USB memory stick. Any calibration file that has been saved in the
ADDAPT program will be loaded into the drive in its entirety. The drive ignores the
“MARKED”/“UNMARKED” attribute of individual drive calibration and configuration
parameters that ADDAPT includes in the “.add” file.
11.5.1 CAL LOAD COMPLETION MESSAGES
Once the loading of calibration and configuration data from the USB memory stick is
initiated, one of the following messages will be displayed:
Message Meaning
>>LOAD FAILED An internal software error is detected during a
cal load operation. Drive calibration/
configuration data is considered invalid.
LD FAIL An attempt to load drive cal/config while the
drive is running failed. No changes are made to
drive cal/configuration.
NO CAL FOUND No file is found in the appropriate USB
memory stick directory with the “.add” file
extension.
NO USB DEV PRSNT No USB memory stick is detectable in the
drive.
>>LOAD ABORTED The CAL LOAD operation is aborted by the
user. No changes are made to drive cal/
configuration.
>>LOAD COMPLETE The operation is successfully completed.
11.6 USB CALIBRATION/CONFIGURATION STORE
The ADDvantage-32 PLUS drive allows the user to store the drive calibration and
configuration information to a file located on the USB memory stick.
To perform a USB flash store of calibration and configuration information to the USB
memory stick, navigate the USB submenu to reach the USB CAL STORE option as
shown below:
USB CAL STORE
------>