Network Interface Connection
Each DACS may contain one or two network interface cards. Network interface cards are PCI
based 10/100Mbs Ethernet cards.
Cable connection is located on the rear of the DACS chassis. Attach your Ethernet network
cable(s) to the RJ45 connector(s). Standard off-the-shelf network cabling can be used to make the
connection. Be sure to use cabling recommended for 100Mbs (Fast) ethernet applications.
Systems with two cards may be configured to direct certain types of data to be transmitted and
received via either the A or B network card. Be sure to determine your network layout and the
type of information on each network before connection. Cards will be marked on the rear of the
chassis and indicated on the Engineering drawings supplied with the system. See the section on
Network Interface in Chapter 2 for more information.
Note: Ethernet connection is not required to run the Model Builder sound model generation soft-
ware. Sound models can be developed and run without network connection, Network card A, how-
ever, must remain installed in order to use the Model Builder sound model environment
Software Installation and Configuration
The ASTi DACS is delivered with an operating system, Model Builder sound model generation
software, Model Server routing configuration files, and in some rare cases, 3rd party software
applications. All software is pre-installed on the Model Processor hard disk. No initial software
installation is required, unless the system was purchased as a “cold” spare. “Hot” spare systems
are delivered fully-configured.
The DACS is preconfigured to run the Model Builder software environment automatically upon
power up or system reboot.
In most cases system and network configuration parameters will also need to be set using the start
up configuration command file. See the back of the Model Builder Reference Guide for more
information.
Disks are provided for all software to accommodate cold start of the system. The diskettes may be
found with the documentation that was delivered with the system(s). For information on how to
reinstall your DACS software and reset your CPU operating parameters in the event of a failure,
see the Cold Start section in Chapter 5, Test and Maintenance.
Note that sound and communications models, system start-up configuration files and cell routing
files are not pre-installed.
Customers who have contracted ASTi to develop models will receive these files on disks as part of
their contract. It will be the responsibility of the customer to install these disks upon receipt.
For sound and communications models developed by the user, the user is responsible for install-
ing and maintaining their own files.