Technical data
ASTi DACS: Operation & Maintenance Manual (Version 4, Rev. B.1) www.asti-usa.com
30 Copyright © 1999-2006 Advanced Simulation Technology inc.
Chapter 4: DACS Operation
This chapter discusses DACS operation. Topics include powering the system up and down, soft-
ware operation, interfacing to a host computer, and external equipment operation.
Powering the DACS Up and Down
Use the following procedures when powering up and down the DACS.
Power Up Sequence
To power up the DACS, perform the following procedure:
• Ensure that there is no disk in the floppy drive.
• For systems using TDM rings and RIUs, the RIUs should be powered up before or at the
same time as the DACS to avoid any possible synchronization problems with the TDM ring.
• Switch on the DACS using the ON/OFF rocker switch or push-button located on the front of
the chassis.
• The Model Builder software environment will start automatically and display the Model
Builder Main Menu shown in “Model Builder Main Menu” on page 35.
• Ensure that all externally connected equipment is powered up as required.
Figure 4: Model Builder Main Menu