User's Manual

Table Of Contents
Battery Pack and Charger
DigiTrak
®
F5
®
Operator’s Manual 13
Battery Charger LED Indicators
LEDs Charger Status Battery Status Charge Time
Orange Power supplied to charger N/A N/A
Solid Red Battery charging 4–16.8 V <38 hr
Flashing Red Battery or communication fault Varies Varies
Solid Green Battery Installed and receiving trickle
charge
16.616.8 V Approaching
full charge
Flashing Green Battery installed and fully charged 16.817 V N/A
(Fully Charged)
Solid Red and
Green
Temperature fault
(see Appendix A for environmental
operating specifications)
Freezing or
Overheated
Will not charge
Removing a Battery Pack or Brace Insert
To remove the battery pack or brace insert from the
FSD remote, F5 receiver, or F Series battery charger,
push the tab towards the face of the battery pack/brace
insert and pull it away from the unit as shown the figure
to the right. When the battery pack/brace insert is
released, grasp it firmly to lift it out of the unit.
Battery Pack Storage
If you plan to store the battery packs for any period of time, please follow the guidelines listed below.
Do not store the battery pack at temperatures greater than 113°F (45°C).
Do not store the battery pack in a fully discharged state.
Do not store the battery pack in the battery charger.
If the battery pack is going to be stored for an extended period of time, pre-charge the battery to a
charge level of 20% to 30% (two to three LEDs illuminated on the battery pack).
Removing Battery Pack or Brace Insert
Note: The brace insert is installed in the FSD
remote when the remote is powered through
the DC power cable. See the Remote Display
section for more information.