Operator’s Manual 25
2 Point Calibration, Obtain 2
nd
Point
6. Lift the receiver 3 ft (or 1m) directly up and click the trigger to initiate calibration of the second point or
toggle right and select the exit option to be returned to the main menu with no change to the
calibration.
After selecting the checkmark, the screen will show that the receiver is calibrating. Do not move the
receiver while it is calibrating. Four short tones and a check mark on the screen indicate a successful
calibration.
After the 2-point calibration procedure has passed, verify the distance between the two calibration points
by taking depth measurements at the first point and the second point and then determining the difference
between the two values. The difference should be 3 ft ± 2 in. (or 1 m ± 5 cm). Repeat these
measurements several times as you continue drilling to verify that the depth remains valid as the pitch of
the transmitter changes.