User's Manual

Table Of Contents
Locating
74 DigiTrak
®
F5 Operator’s Manual
3. Observe the position of the locating target ( ) relative to the receiver box on the display. The figures
below illustrate what you might see on the display and the actual position of the receiver, transmitter,
and locate points. Note that the FLP is ahead of and to the left of the receiver, as shown in the
receiver display.
RLP
FLP
LL
Receiver Locate Mode Screen
Actual Position of
Receiver and Transmitter
4. Walk in the direction indicated by the picture on the screen to center the target in the box, which is
forward and to the left in this example.
5. When the target is centered in the box, hold the trigger in for one second so the receiver can get a
“lock” on the reference signal. The “R” symbol will appear at the top of the depth screen.
WARNING: Do not hold the trigger in unless you are precisely at the FLP (target centered in box). If
you are ahead of the FLP, you could set an incorrect reference that causes a ghost
locate line. In this case, you must reference again at the FLP.
RLP
FLP
LL
Receiver Depth Mode Screen
(at FLP with HAG on)
Actual Position of
Receiver and Transmitter
Locating
“target”
“Box”
Target-in-